Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes

Dmytro Bavol, Jiri Zima, Jiri Barek, Hana Dejmkova

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.

Original languageEnglish
Pages (from-to)1029-1034
Number of pages6
JournalElectroanalysis
Volume28
Issue number5
DOIs
Publication statusPublished - 1 May 2016
Externally publishedYes

Fingerprint

Carbon
Voltammetry
Electrodes
Ointments
Carbon fibers
Pesticides
Rivers
Soils
2-cyano-N-((ethylamino)carbonyl)-2-(methoxyimino)acetamide
famoxadon
Water
carbon fiber

Keywords

  • Carbon fiber rod electrode
  • Carbon paste electrode
  • Differential pulse voltammetry
  • Glassy carbon electrode
  • Pesticide

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Cite this

Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes. / Bavol, Dmytro; Zima, Jiri; Barek, Jiri; Dejmkova, Hana.

In: Electroanalysis, Vol. 28, No. 5, 01.05.2016, p. 1029-1034.

Research output: Contribution to journalArticle

Bavol, Dmytro ; Zima, Jiri ; Barek, Jiri ; Dejmkova, Hana. / Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes. In: Electroanalysis. 2016 ; Vol. 28, No. 5. pp. 1029-1034.
@article{e150008312834b6a8af754593623387b,
title = "Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes",
abstract = "Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.",
keywords = "Carbon fiber rod electrode, Carbon paste electrode, Differential pulse voltammetry, Glassy carbon electrode, Pesticide",
author = "Dmytro Bavol and Jiri Zima and Jiri Barek and Hana Dejmkova",
year = "2016",
month = "5",
day = "1",
doi = "10.1002/elan.201500633",
language = "English",
volume = "28",
pages = "1029--1034",
journal = "Macromolecular Chemistry and Physics",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "5",

}

TY - JOUR

T1 - Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes

AU - Bavol, Dmytro

AU - Zima, Jiri

AU - Barek, Jiri

AU - Dejmkova, Hana

PY - 2016/5/1

Y1 - 2016/5/1

N2 - Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.

AB - Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.

KW - Carbon fiber rod electrode

KW - Carbon paste electrode

KW - Differential pulse voltammetry

KW - Glassy carbon electrode

KW - Pesticide

UR - http://www.scopus.com/inward/record.url?scp=84950349869&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84950349869&partnerID=8YFLogxK

U2 - 10.1002/elan.201500633

DO - 10.1002/elan.201500633

M3 - Article

AN - SCOPUS:84950349869

VL - 28

SP - 1029

EP - 1034

JO - Macromolecular Chemistry and Physics

JF - Macromolecular Chemistry and Physics

SN - 1040-0397

IS - 5

ER -