Voltammetric and amperometric determination of selected dinitronaphthalenes using single crystal silver amalgam based sensors

Jana Tvrdikova, Ales Danhel, Jiri Barek, Vlastimil Vyskocil

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Modern voltammetric techniques, combined with the quasi-cylindrical single crystal silver amalgam electrode (CAgAE) tested, were used for determination of selected environmental pollutants, 1,3-dinitronaphthalene, 1,5- dinitronaphthalene and 1,8-dinitronaphthalene. The optimum conditions were found for the determination of selected dinitronaphthalenes (DNNs) using direct current voltammetry and differential pulse voltammetry. The procedures were applied to determination of these analytes in model samples of tap water. The 1,3-, 1,5- and 1,8-DNN were determined by differential pulse voltammetry (DPV) with limits of quantification 1.0, 1.0 and 0.3 μmol l -1 in concentration range up to 100 μmol l -1 in Britton-Robinson buffer and methanol mixture (1:1) with final pH 8.2, 12.3 and 8.2, respectively. The 1,3-, 1,5- and 1,8-DNN were then determined by DPV with limits of quantification 0.4, 0.5 and 0.4 μmol l -1 in model samples of tap water conditioned by Britton-Robinson buffer (9:1) pH 7.0, 12.0 and 7.0, respectively, in presence of 0.001 mol l -1 Na 2EDTA. Adsorptive stripping differential pulse voltammetry was unsuccessfully tested in an attempt to obtain lower limits of quantification. The processes occurring during the DNNs reduction at the CAgAE were also investigated by cyclic voltammetry. A single crystal of the silver amalgam was then used to design a cylindrical flow-through detector which was utilized for amperometric detection of selected DNNs in a mixture, after their separation by conventional HPLC. The optimum separation and detection conditions for the DNNs at the cylindrical flow-through detector were found. The DNNs were separated using column with reverse phase C-18, ammonium acetate pH 4.7-methanol (27:73) as mobile phase at flow rate 1.5 ml min -1 and detected by the cylindrical detector at potential -1.2 V with limit of detection 1 μmol l -1 within concentration range up to 100 μmol l -1. Single-crystal silver amalgam was found to be a suitable alternative for "toxic" mercury in voltammetric measurements and a convenient electrode material for designing a new amperometric detector.

Original languageEnglish
Pages (from-to)23-30
Number of pages8
JournalElectrochimica Acta
Volume73
DOIs
Publication statusPublished - 1 Jul 2012
Externally publishedYes

Fingerprint

Mercury amalgams
Voltammetry
Silver
Single crystals
Sensors
Detectors
Electrodes
Methanol
Buffers
Environmental Pollutants
Water
Poisons
Mercury
Cyclic voltammetry
Flow rate
Crystals
1,5-dinitronaphthalene
1,8-dinitronaphthalene

Keywords

  • Amperometry
  • Dinitronaphthalenes
  • Nitrated polycyclic aromatic hydrocarbons
  • Single crystal silver amalgam electrode
  • Voltammetry

ASJC Scopus subject areas

  • Chemical Engineering(all)
  • Electrochemistry

Cite this

Voltammetric and amperometric determination of selected dinitronaphthalenes using single crystal silver amalgam based sensors. / Tvrdikova, Jana; Danhel, Ales; Barek, Jiri; Vyskocil, Vlastimil.

In: Electrochimica Acta, Vol. 73, 01.07.2012, p. 23-30.

Research output: Contribution to journalArticle

@article{834602be6cd0410fa50851322dc21ed7,
title = "Voltammetric and amperometric determination of selected dinitronaphthalenes using single crystal silver amalgam based sensors",
abstract = "Modern voltammetric techniques, combined with the quasi-cylindrical single crystal silver amalgam electrode (CAgAE) tested, were used for determination of selected environmental pollutants, 1,3-dinitronaphthalene, 1,5- dinitronaphthalene and 1,8-dinitronaphthalene. The optimum conditions were found for the determination of selected dinitronaphthalenes (DNNs) using direct current voltammetry and differential pulse voltammetry. The procedures were applied to determination of these analytes in model samples of tap water. The 1,3-, 1,5- and 1,8-DNN were determined by differential pulse voltammetry (DPV) with limits of quantification 1.0, 1.0 and 0.3 μmol l -1 in concentration range up to 100 μmol l -1 in Britton-Robinson buffer and methanol mixture (1:1) with final pH 8.2, 12.3 and 8.2, respectively. The 1,3-, 1,5- and 1,8-DNN were then determined by DPV with limits of quantification 0.4, 0.5 and 0.4 μmol l -1 in model samples of tap water conditioned by Britton-Robinson buffer (9:1) pH 7.0, 12.0 and 7.0, respectively, in presence of 0.001 mol l -1 Na 2EDTA. Adsorptive stripping differential pulse voltammetry was unsuccessfully tested in an attempt to obtain lower limits of quantification. The processes occurring during the DNNs reduction at the CAgAE were also investigated by cyclic voltammetry. A single crystal of the silver amalgam was then used to design a cylindrical flow-through detector which was utilized for amperometric detection of selected DNNs in a mixture, after their separation by conventional HPLC. The optimum separation and detection conditions for the DNNs at the cylindrical flow-through detector were found. The DNNs were separated using column with reverse phase C-18, ammonium acetate pH 4.7-methanol (27:73) as mobile phase at flow rate 1.5 ml min -1 and detected by the cylindrical detector at potential -1.2 V with limit of detection 1 μmol l -1 within concentration range up to 100 μmol l -1. Single-crystal silver amalgam was found to be a suitable alternative for {"}toxic{"} mercury in voltammetric measurements and a convenient electrode material for designing a new amperometric detector.",
keywords = "Amperometry, Dinitronaphthalenes, Nitrated polycyclic aromatic hydrocarbons, Single crystal silver amalgam electrode, Voltammetry",
author = "Jana Tvrdikova and Ales Danhel and Jiri Barek and Vlastimil Vyskocil",
year = "2012",
month = "7",
day = "1",
doi = "10.1016/j.electacta.2011.09.074",
language = "English",
volume = "73",
pages = "23--30",
journal = "Electrochimica Acta",
issn = "0013-4686",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Voltammetric and amperometric determination of selected dinitronaphthalenes using single crystal silver amalgam based sensors

AU - Tvrdikova, Jana

AU - Danhel, Ales

AU - Barek, Jiri

AU - Vyskocil, Vlastimil

PY - 2012/7/1

Y1 - 2012/7/1

N2 - Modern voltammetric techniques, combined with the quasi-cylindrical single crystal silver amalgam electrode (CAgAE) tested, were used for determination of selected environmental pollutants, 1,3-dinitronaphthalene, 1,5- dinitronaphthalene and 1,8-dinitronaphthalene. The optimum conditions were found for the determination of selected dinitronaphthalenes (DNNs) using direct current voltammetry and differential pulse voltammetry. The procedures were applied to determination of these analytes in model samples of tap water. The 1,3-, 1,5- and 1,8-DNN were determined by differential pulse voltammetry (DPV) with limits of quantification 1.0, 1.0 and 0.3 μmol l -1 in concentration range up to 100 μmol l -1 in Britton-Robinson buffer and methanol mixture (1:1) with final pH 8.2, 12.3 and 8.2, respectively. The 1,3-, 1,5- and 1,8-DNN were then determined by DPV with limits of quantification 0.4, 0.5 and 0.4 μmol l -1 in model samples of tap water conditioned by Britton-Robinson buffer (9:1) pH 7.0, 12.0 and 7.0, respectively, in presence of 0.001 mol l -1 Na 2EDTA. Adsorptive stripping differential pulse voltammetry was unsuccessfully tested in an attempt to obtain lower limits of quantification. The processes occurring during the DNNs reduction at the CAgAE were also investigated by cyclic voltammetry. A single crystal of the silver amalgam was then used to design a cylindrical flow-through detector which was utilized for amperometric detection of selected DNNs in a mixture, after their separation by conventional HPLC. The optimum separation and detection conditions for the DNNs at the cylindrical flow-through detector were found. The DNNs were separated using column with reverse phase C-18, ammonium acetate pH 4.7-methanol (27:73) as mobile phase at flow rate 1.5 ml min -1 and detected by the cylindrical detector at potential -1.2 V with limit of detection 1 μmol l -1 within concentration range up to 100 μmol l -1. Single-crystal silver amalgam was found to be a suitable alternative for "toxic" mercury in voltammetric measurements and a convenient electrode material for designing a new amperometric detector.

AB - Modern voltammetric techniques, combined with the quasi-cylindrical single crystal silver amalgam electrode (CAgAE) tested, were used for determination of selected environmental pollutants, 1,3-dinitronaphthalene, 1,5- dinitronaphthalene and 1,8-dinitronaphthalene. The optimum conditions were found for the determination of selected dinitronaphthalenes (DNNs) using direct current voltammetry and differential pulse voltammetry. The procedures were applied to determination of these analytes in model samples of tap water. The 1,3-, 1,5- and 1,8-DNN were determined by differential pulse voltammetry (DPV) with limits of quantification 1.0, 1.0 and 0.3 μmol l -1 in concentration range up to 100 μmol l -1 in Britton-Robinson buffer and methanol mixture (1:1) with final pH 8.2, 12.3 and 8.2, respectively. The 1,3-, 1,5- and 1,8-DNN were then determined by DPV with limits of quantification 0.4, 0.5 and 0.4 μmol l -1 in model samples of tap water conditioned by Britton-Robinson buffer (9:1) pH 7.0, 12.0 and 7.0, respectively, in presence of 0.001 mol l -1 Na 2EDTA. Adsorptive stripping differential pulse voltammetry was unsuccessfully tested in an attempt to obtain lower limits of quantification. The processes occurring during the DNNs reduction at the CAgAE were also investigated by cyclic voltammetry. A single crystal of the silver amalgam was then used to design a cylindrical flow-through detector which was utilized for amperometric detection of selected DNNs in a mixture, after their separation by conventional HPLC. The optimum separation and detection conditions for the DNNs at the cylindrical flow-through detector were found. The DNNs were separated using column with reverse phase C-18, ammonium acetate pH 4.7-methanol (27:73) as mobile phase at flow rate 1.5 ml min -1 and detected by the cylindrical detector at potential -1.2 V with limit of detection 1 μmol l -1 within concentration range up to 100 μmol l -1. Single-crystal silver amalgam was found to be a suitable alternative for "toxic" mercury in voltammetric measurements and a convenient electrode material for designing a new amperometric detector.

KW - Amperometry

KW - Dinitronaphthalenes

KW - Nitrated polycyclic aromatic hydrocarbons

KW - Single crystal silver amalgam electrode

KW - Voltammetry

UR - http://www.scopus.com/inward/record.url?scp=84861349027&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84861349027&partnerID=8YFLogxK

U2 - 10.1016/j.electacta.2011.09.074

DO - 10.1016/j.electacta.2011.09.074

M3 - Article

VL - 73

SP - 23

EP - 30

JO - Electrochimica Acta

JF - Electrochimica Acta

SN - 0013-4686