Vertical beam size measurement at CesrTA using diffraction radiation

L. Bobb, T. Aumeyr, P. Karataev, E. Bravin, T. Lefevre, S. Mazzoni, H. Schmickler, M. Billing, J. Conway

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Over recent years the first Diffraction Radiation (DR) beam size monitor has been tested on a circular machine. At CesrTA, Cornell University, USA, the sensitivity and limitations of the DR monitor for vertical beam size measurement has been investigated. DR emitted from 1 and 0:5 mm target apertures was observed at 400 and 600 nm wavelengths. In addition, interference between the DR signals emitted by the target and mask has been observed. In this report, we present the recent observations and discuss areas for improvement.

Original languageEnglish
Title of host publicationInternational Beam Instrumentation Conference, IBIC 2014
PublisherSLAC National Accelerator Laboratory
Publication statusPublished - 2014
Externally publishedYes
Event3rd International Beam Instrumentation Conference, IBIC 2014 - Monterey, United States
Duration: 14 Sep 201418 Sep 2014

Conference

Conference3rd International Beam Instrumentation Conference, IBIC 2014
CountryUnited States
CityMonterey
Period14.9.1418.9.14

Fingerprint

diffraction radiation
Diffraction
Radiation
monitors
Wave interference
Masks
masks
apertures
interference
Wavelength
sensitivity
wavelengths

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Bobb, L., Aumeyr, T., Karataev, P., Bravin, E., Lefevre, T., Mazzoni, S., ... Conway, J. (2014). Vertical beam size measurement at CesrTA using diffraction radiation. In International Beam Instrumentation Conference, IBIC 2014 SLAC National Accelerator Laboratory.

Vertical beam size measurement at CesrTA using diffraction radiation. / Bobb, L.; Aumeyr, T.; Karataev, P.; Bravin, E.; Lefevre, T.; Mazzoni, S.; Schmickler, H.; Billing, M.; Conway, J.

International Beam Instrumentation Conference, IBIC 2014. SLAC National Accelerator Laboratory, 2014.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Bobb, L, Aumeyr, T, Karataev, P, Bravin, E, Lefevre, T, Mazzoni, S, Schmickler, H, Billing, M & Conway, J 2014, Vertical beam size measurement at CesrTA using diffraction radiation. in International Beam Instrumentation Conference, IBIC 2014. SLAC National Accelerator Laboratory, 3rd International Beam Instrumentation Conference, IBIC 2014, Monterey, United States, 14.9.14.
Bobb L, Aumeyr T, Karataev P, Bravin E, Lefevre T, Mazzoni S et al. Vertical beam size measurement at CesrTA using diffraction radiation. In International Beam Instrumentation Conference, IBIC 2014. SLAC National Accelerator Laboratory. 2014
Bobb, L. ; Aumeyr, T. ; Karataev, P. ; Bravin, E. ; Lefevre, T. ; Mazzoni, S. ; Schmickler, H. ; Billing, M. ; Conway, J. / Vertical beam size measurement at CesrTA using diffraction radiation. International Beam Instrumentation Conference, IBIC 2014. SLAC National Accelerator Laboratory, 2014.
@inproceedings{2f6b1d655fae4e79b3a9b5db073129be,
title = "Vertical beam size measurement at CesrTA using diffraction radiation",
abstract = "Over recent years the first Diffraction Radiation (DR) beam size monitor has been tested on a circular machine. At CesrTA, Cornell University, USA, the sensitivity and limitations of the DR monitor for vertical beam size measurement has been investigated. DR emitted from 1 and 0:5 mm target apertures was observed at 400 and 600 nm wavelengths. In addition, interference between the DR signals emitted by the target and mask has been observed. In this report, we present the recent observations and discuss areas for improvement.",
author = "L. Bobb and T. Aumeyr and P. Karataev and E. Bravin and T. Lefevre and S. Mazzoni and H. Schmickler and M. Billing and J. Conway",
year = "2014",
language = "English",
booktitle = "International Beam Instrumentation Conference, IBIC 2014",
publisher = "SLAC National Accelerator Laboratory",

}

TY - GEN

T1 - Vertical beam size measurement at CesrTA using diffraction radiation

AU - Bobb, L.

AU - Aumeyr, T.

AU - Karataev, P.

AU - Bravin, E.

AU - Lefevre, T.

AU - Mazzoni, S.

AU - Schmickler, H.

AU - Billing, M.

AU - Conway, J.

PY - 2014

Y1 - 2014

N2 - Over recent years the first Diffraction Radiation (DR) beam size monitor has been tested on a circular machine. At CesrTA, Cornell University, USA, the sensitivity and limitations of the DR monitor for vertical beam size measurement has been investigated. DR emitted from 1 and 0:5 mm target apertures was observed at 400 and 600 nm wavelengths. In addition, interference between the DR signals emitted by the target and mask has been observed. In this report, we present the recent observations and discuss areas for improvement.

AB - Over recent years the first Diffraction Radiation (DR) beam size monitor has been tested on a circular machine. At CesrTA, Cornell University, USA, the sensitivity and limitations of the DR monitor for vertical beam size measurement has been investigated. DR emitted from 1 and 0:5 mm target apertures was observed at 400 and 600 nm wavelengths. In addition, interference between the DR signals emitted by the target and mask has been observed. In this report, we present the recent observations and discuss areas for improvement.

UR - http://www.scopus.com/inward/record.url?scp=84920722343&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920722343&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84920722343

BT - International Beam Instrumentation Conference, IBIC 2014

PB - SLAC National Accelerator Laboratory

ER -