UTILIZATION OF SEQUENTIAL COMMUTATION OF PHASES OF A THREE-PHASE PULSE GENERATOR OPERATING INTO AN INDUCTIVE LOAD.

A. I. Chuchalin, A. V. Loos, G. A. Sipailov

Research output: Contribution to journalArticle

Abstract

The question of using a three-phase pulse generator in a nonsymmetric regime through sequential commutation of the phases is considered for an inductive load, as one possible way of raising the effectiveness of generator utilization in step operation.

Original languageEnglish
Pages (from-to)42-48
Number of pages7
JournalSoviet electrical engineering
Volume50
Issue number5
Publication statusPublished - 1979

Fingerprint

Pulse generators
Electric commutation

ASJC Scopus subject areas

  • Engineering(all)

Cite this

UTILIZATION OF SEQUENTIAL COMMUTATION OF PHASES OF A THREE-PHASE PULSE GENERATOR OPERATING INTO AN INDUCTIVE LOAD. / Chuchalin, A. I.; Loos, A. V.; Sipailov, G. A.

In: Soviet electrical engineering, Vol. 50, No. 5, 1979, p. 42-48.

Research output: Contribution to journalArticle

@article{ec63aedac807473ead1c314f41717648,
title = "UTILIZATION OF SEQUENTIAL COMMUTATION OF PHASES OF A THREE-PHASE PULSE GENERATOR OPERATING INTO AN INDUCTIVE LOAD.",
abstract = "The question of using a three-phase pulse generator in a nonsymmetric regime through sequential commutation of the phases is considered for an inductive load, as one possible way of raising the effectiveness of generator utilization in step operation.",
author = "Chuchalin, {A. I.} and Loos, {A. V.} and Sipailov, {G. A.}",
year = "1979",
language = "English",
volume = "50",
pages = "42--48",
journal = "Soviet electrical engineering",
issn = "0038-5379",
publisher = "Allerton Press Inc.",
number = "5",

}

TY - JOUR

T1 - UTILIZATION OF SEQUENTIAL COMMUTATION OF PHASES OF A THREE-PHASE PULSE GENERATOR OPERATING INTO AN INDUCTIVE LOAD.

AU - Chuchalin, A. I.

AU - Loos, A. V.

AU - Sipailov, G. A.

PY - 1979

Y1 - 1979

N2 - The question of using a three-phase pulse generator in a nonsymmetric regime through sequential commutation of the phases is considered for an inductive load, as one possible way of raising the effectiveness of generator utilization in step operation.

AB - The question of using a three-phase pulse generator in a nonsymmetric regime through sequential commutation of the phases is considered for an inductive load, as one possible way of raising the effectiveness of generator utilization in step operation.