Abstract

This article presents theoretical grounds and experimental studies on the development of a diagnostic method for liquid media based on photometry of samples as lying drops. The basic mechanisms of the effects of processes taking place in drop samples on their optical properties are discussed. Results obtained from verification tests of the drop photometry method for assessment of RBC sedimentation dynamics and the process of fibrin clot formation in clotting tests are presented.

Original languageEnglish
Pages (from-to)1-4
Number of pages4
JournalBiomedical Engineering
DOIs
Publication statusAccepted/In press - 20 Jan 2017

Fingerprint

Clinical laboratories
Photometry
Fibrin
Sedimentation
Optical properties
Liquids

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Biomedical Engineering
  • Medical Laboratory Technology

Cite this

Use of Lying Drop Photometry for Clinical Laboratory Diagnostics. / Aristov, A. A.; Nosova, E. V.; Soldatov, A. N.

In: Biomedical Engineering, 20.01.2017, p. 1-4.

Research output: Contribution to journalArticle

@article{c7c06c3447544066b99898b491cbbe37,
title = "Use of Lying Drop Photometry for Clinical Laboratory Diagnostics",
abstract = "This article presents theoretical grounds and experimental studies on the development of a diagnostic method for liquid media based on photometry of samples as lying drops. The basic mechanisms of the effects of processes taking place in drop samples on their optical properties are discussed. Results obtained from verification tests of the drop photometry method for assessment of RBC sedimentation dynamics and the process of fibrin clot formation in clotting tests are presented.",
author = "Aristov, {A. A.} and Nosova, {E. V.} and Soldatov, {A. N.}",
year = "2017",
month = "1",
day = "20",
doi = "10.1007/s10527-017-9645-3",
language = "English",
pages = "1--4",
journal = "Bio-Medical Engineering",
issn = "0006-3398",
publisher = "Springer New York",

}

TY - JOUR

T1 - Use of Lying Drop Photometry for Clinical Laboratory Diagnostics

AU - Aristov, A. A.

AU - Nosova, E. V.

AU - Soldatov, A. N.

PY - 2017/1/20

Y1 - 2017/1/20

N2 - This article presents theoretical grounds and experimental studies on the development of a diagnostic method for liquid media based on photometry of samples as lying drops. The basic mechanisms of the effects of processes taking place in drop samples on their optical properties are discussed. Results obtained from verification tests of the drop photometry method for assessment of RBC sedimentation dynamics and the process of fibrin clot formation in clotting tests are presented.

AB - This article presents theoretical grounds and experimental studies on the development of a diagnostic method for liquid media based on photometry of samples as lying drops. The basic mechanisms of the effects of processes taking place in drop samples on their optical properties are discussed. Results obtained from verification tests of the drop photometry method for assessment of RBC sedimentation dynamics and the process of fibrin clot formation in clotting tests are presented.

UR - http://www.scopus.com/inward/record.url?scp=85009876038&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85009876038&partnerID=8YFLogxK

U2 - 10.1007/s10527-017-9645-3

DO - 10.1007/s10527-017-9645-3

M3 - Article

SP - 1

EP - 4

JO - Bio-Medical Engineering

JF - Bio-Medical Engineering

SN - 0006-3398

ER -