Transition radiation from a cylindrical target and transverse beam size diagnostics

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

In this paper we propose to use backward transition radiation from a cylindrical target in EUV region in order to determine transverse beam size without any additional optics.

Original languageEnglish
Title of host publicationDIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators
Pages410-412
Number of pages3
Publication statusPublished - 2011
Event10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, DIPAC 2011 - Hamburg, Germany
Duration: 16 May 201118 May 2011

Other

Other10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, DIPAC 2011
CountryGermany
CityHamburg
Period16.5.1118.5.11

Fingerprint

Optics
optics
Radiation
radiation

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Potylitsyn, A. P., & Sukhikh, L. G. (2011). Transition radiation from a cylindrical target and transverse beam size diagnostics. In DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators (pp. 410-412)

Transition radiation from a cylindrical target and transverse beam size diagnostics. / Potylitsyn, A. P.; Sukhikh, L. G.

DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators. 2011. p. 410-412.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Potylitsyn, AP & Sukhikh, LG 2011, Transition radiation from a cylindrical target and transverse beam size diagnostics. in DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators. pp. 410-412, 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators, DIPAC 2011, Hamburg, Germany, 16.5.11.
Potylitsyn AP, Sukhikh LG. Transition radiation from a cylindrical target and transverse beam size diagnostics. In DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators. 2011. p. 410-412
Potylitsyn, A. P. ; Sukhikh, L. G. / Transition radiation from a cylindrical target and transverse beam size diagnostics. DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators. 2011. pp. 410-412
@inproceedings{bda8a6781a934f26bcedd643bc96ef9a,
title = "Transition radiation from a cylindrical target and transverse beam size diagnostics",
abstract = "In this paper we propose to use backward transition radiation from a cylindrical target in EUV region in order to determine transverse beam size without any additional optics.",
author = "Potylitsyn, {A. P.} and Sukhikh, {L. G.}",
year = "2011",
language = "English",
pages = "410--412",
booktitle = "DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators",

}

TY - GEN

T1 - Transition radiation from a cylindrical target and transverse beam size diagnostics

AU - Potylitsyn, A. P.

AU - Sukhikh, L. G.

PY - 2011

Y1 - 2011

N2 - In this paper we propose to use backward transition radiation from a cylindrical target in EUV region in order to determine transverse beam size without any additional optics.

AB - In this paper we propose to use backward transition radiation from a cylindrical target in EUV region in order to determine transverse beam size without any additional optics.

UR - http://www.scopus.com/inward/record.url?scp=84880350722&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880350722&partnerID=8YFLogxK

M3 - Conference contribution

SP - 410

EP - 412

BT - DIPAC 2011 - Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators

ER -