THEORETICAL AND EXPERIMENTAL RATING OF THE SENSITIVITY OF THERMAL INSPECTION OF NONMETALLIC PLATES.

V. P. Vavilov, V. I. Gorbunov, S. Yu Tanaseichuk, V. V. Shiryaev

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

A mathematical model is proposed for the process of thermal inspection of nometallic plates; with its help the basic relationships of temperature drops wre investigated. Using as an example the inspection of getinax plates, calculated and experimental data on the measurement of temperature fields are compared; on this basis conclusions are drawn about the possibilities of the thermal method.

Original languageEnglish
Title of host publicationSov J Nondestr Test
Pages416-420
Number of pages5
Volume13
Edition4
Publication statusPublished - Jul 1977