The use of silver solid amalgam electrode for voltammetric and amperometric determination of nitroquinolines

Ivan Jiranek, Karolina Peckova, Zuzana Kralova, Josino C. Moreira, Jiri Barek

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

Solid amalgam electrodes represent a suitable alternative to mercury electrodes due to their similar electrochemical properties and non-toxicity of the amalgam material. Nitro derivatives of quinoline have been proven to be genotoxic, thus their presence in environmental samples is a legitimate cause for concern. In this contribution, meniscus modified silver solid amalgam electrode (m-AgSAE) was employed for the batch voltammetric determination and amperometric determination in connection with flow injection analysis of 5-nitroquinoline and 6-nitroquinoline (5-NQ, 6-NQ). Their electrochemical behavior was characterized by cyclic voltammetry, for their determination direct current voltammetry and differential pulse voltammetry were used. Linear calibration curves in the concentration range of 2 × 10-7 to 1 × 10-4 mol L-1 were obtained. These results are comparable with results obtained for polarographic determination of the same substances using mercury electrodes. Further, the meniscus modified silver solid amalgam electrode was employed in amperometric detection cell in "wall jet" arrangement for determination of 5-NQ in flow injection analysis. Under optimized conditions (run buffer 0.05 mol L-1 borate buffer, pH 9.0; flow rate 4 mL min-1; detection potential -1.6 V; injection volume 0.1 mL), the limit of quantitation of ∼4 × 10-6 mol L-1 was achieved. The repeatability of the detector response is satisfactory (relative standard deviation ∼2.15% for c(5-NQ) = 1 × 10-4 mol L-1). Practical applicability of the method was verified for the determination of micromolar concentrations of 5-NQ in drinking and river water model samples.

Original languageEnglish
Pages (from-to)1939-1947
Number of pages9
JournalElectrochimica Acta
Volume54
Issue number7
DOIs
Publication statusPublished - 28 Feb 2009
Externally publishedYes

Fingerprint

Nitroquinolines
Mercury amalgams
Silver
Electrodes
Voltammetry
Mercury
Buffers
Borates
Mercury (metal)
Electrochemical properties
Cyclic voltammetry
Rivers
Flow rate
Calibration
Derivatives
Detectors
Water

Keywords

  • 5-Nitroquinoline
  • 6-Nitroquinoline
  • Flow injection analysis
  • Silver solid amalgam electrode
  • Voltammetry

ASJC Scopus subject areas

  • Chemical Engineering(all)
  • Electrochemistry

Cite this

The use of silver solid amalgam electrode for voltammetric and amperometric determination of nitroquinolines. / Jiranek, Ivan; Peckova, Karolina; Kralova, Zuzana; Moreira, Josino C.; Barek, Jiri.

In: Electrochimica Acta, Vol. 54, No. 7, 28.02.2009, p. 1939-1947.

Research output: Contribution to journalArticle

Jiranek, Ivan ; Peckova, Karolina ; Kralova, Zuzana ; Moreira, Josino C. ; Barek, Jiri. / The use of silver solid amalgam electrode for voltammetric and amperometric determination of nitroquinolines. In: Electrochimica Acta. 2009 ; Vol. 54, No. 7. pp. 1939-1947.
@article{2122bc4d293a4b249397826d996b44cc,
title = "The use of silver solid amalgam electrode for voltammetric and amperometric determination of nitroquinolines",
abstract = "Solid amalgam electrodes represent a suitable alternative to mercury electrodes due to their similar electrochemical properties and non-toxicity of the amalgam material. Nitro derivatives of quinoline have been proven to be genotoxic, thus their presence in environmental samples is a legitimate cause for concern. In this contribution, meniscus modified silver solid amalgam electrode (m-AgSAE) was employed for the batch voltammetric determination and amperometric determination in connection with flow injection analysis of 5-nitroquinoline and 6-nitroquinoline (5-NQ, 6-NQ). Their electrochemical behavior was characterized by cyclic voltammetry, for their determination direct current voltammetry and differential pulse voltammetry were used. Linear calibration curves in the concentration range of 2 × 10-7 to 1 × 10-4 mol L-1 were obtained. These results are comparable with results obtained for polarographic determination of the same substances using mercury electrodes. Further, the meniscus modified silver solid amalgam electrode was employed in amperometric detection cell in {"}wall jet{"} arrangement for determination of 5-NQ in flow injection analysis. Under optimized conditions (run buffer 0.05 mol L-1 borate buffer, pH 9.0; flow rate 4 mL min-1; detection potential -1.6 V; injection volume 0.1 mL), the limit of quantitation of ∼4 × 10-6 mol L-1 was achieved. The repeatability of the detector response is satisfactory (relative standard deviation ∼2.15{\%} for c(5-NQ) = 1 × 10-4 mol L-1). Practical applicability of the method was verified for the determination of micromolar concentrations of 5-NQ in drinking and river water model samples.",
keywords = "5-Nitroquinoline, 6-Nitroquinoline, Flow injection analysis, Silver solid amalgam electrode, Voltammetry",
author = "Ivan Jiranek and Karolina Peckova and Zuzana Kralova and Moreira, {Josino C.} and Jiri Barek",
year = "2009",
month = "2",
day = "28",
doi = "10.1016/j.electacta.2008.08.022",
language = "English",
volume = "54",
pages = "1939--1947",
journal = "Electrochimica Acta",
issn = "0013-4686",
publisher = "Elsevier Limited",
number = "7",

}

TY - JOUR

T1 - The use of silver solid amalgam electrode for voltammetric and amperometric determination of nitroquinolines

AU - Jiranek, Ivan

AU - Peckova, Karolina

AU - Kralova, Zuzana

AU - Moreira, Josino C.

AU - Barek, Jiri

PY - 2009/2/28

Y1 - 2009/2/28

N2 - Solid amalgam electrodes represent a suitable alternative to mercury electrodes due to their similar electrochemical properties and non-toxicity of the amalgam material. Nitro derivatives of quinoline have been proven to be genotoxic, thus their presence in environmental samples is a legitimate cause for concern. In this contribution, meniscus modified silver solid amalgam electrode (m-AgSAE) was employed for the batch voltammetric determination and amperometric determination in connection with flow injection analysis of 5-nitroquinoline and 6-nitroquinoline (5-NQ, 6-NQ). Their electrochemical behavior was characterized by cyclic voltammetry, for their determination direct current voltammetry and differential pulse voltammetry were used. Linear calibration curves in the concentration range of 2 × 10-7 to 1 × 10-4 mol L-1 were obtained. These results are comparable with results obtained for polarographic determination of the same substances using mercury electrodes. Further, the meniscus modified silver solid amalgam electrode was employed in amperometric detection cell in "wall jet" arrangement for determination of 5-NQ in flow injection analysis. Under optimized conditions (run buffer 0.05 mol L-1 borate buffer, pH 9.0; flow rate 4 mL min-1; detection potential -1.6 V; injection volume 0.1 mL), the limit of quantitation of ∼4 × 10-6 mol L-1 was achieved. The repeatability of the detector response is satisfactory (relative standard deviation ∼2.15% for c(5-NQ) = 1 × 10-4 mol L-1). Practical applicability of the method was verified for the determination of micromolar concentrations of 5-NQ in drinking and river water model samples.

AB - Solid amalgam electrodes represent a suitable alternative to mercury electrodes due to their similar electrochemical properties and non-toxicity of the amalgam material. Nitro derivatives of quinoline have been proven to be genotoxic, thus their presence in environmental samples is a legitimate cause for concern. In this contribution, meniscus modified silver solid amalgam electrode (m-AgSAE) was employed for the batch voltammetric determination and amperometric determination in connection with flow injection analysis of 5-nitroquinoline and 6-nitroquinoline (5-NQ, 6-NQ). Their electrochemical behavior was characterized by cyclic voltammetry, for their determination direct current voltammetry and differential pulse voltammetry were used. Linear calibration curves in the concentration range of 2 × 10-7 to 1 × 10-4 mol L-1 were obtained. These results are comparable with results obtained for polarographic determination of the same substances using mercury electrodes. Further, the meniscus modified silver solid amalgam electrode was employed in amperometric detection cell in "wall jet" arrangement for determination of 5-NQ in flow injection analysis. Under optimized conditions (run buffer 0.05 mol L-1 borate buffer, pH 9.0; flow rate 4 mL min-1; detection potential -1.6 V; injection volume 0.1 mL), the limit of quantitation of ∼4 × 10-6 mol L-1 was achieved. The repeatability of the detector response is satisfactory (relative standard deviation ∼2.15% for c(5-NQ) = 1 × 10-4 mol L-1). Practical applicability of the method was verified for the determination of micromolar concentrations of 5-NQ in drinking and river water model samples.

KW - 5-Nitroquinoline

KW - 6-Nitroquinoline

KW - Flow injection analysis

KW - Silver solid amalgam electrode

KW - Voltammetry

UR - http://www.scopus.com/inward/record.url?scp=59749099272&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=59749099272&partnerID=8YFLogxK

U2 - 10.1016/j.electacta.2008.08.022

DO - 10.1016/j.electacta.2008.08.022

M3 - Article

AN - SCOPUS:59749099272

VL - 54

SP - 1939

EP - 1947

JO - Electrochimica Acta

JF - Electrochimica Acta

SN - 0013-4686

IS - 7

ER -