The Mathematical Model of Image, Generated by Scanning Digital Radiography System

V. A. Udod, S. P. Osipov, Yanzhao Wang

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The mathematical model of image, generated by scanning digital radiography system is present. This model takes into account the X-ray energy spectrum transformation of the test object and a noise due to the quantum nature of radiation. The calculation results confirm the importance of fluctuations of the absorbed energy of the registered photon for the small size of the scintillation detectors.

Original languageEnglish
Article number012042
JournalIOP Conference Series: Materials Science and Engineering
Volume168
Issue number1
DOIs
Publication statusPublished - 7 Feb 2017

Fingerprint

Scintillation counters
Radiography
Photons
Mathematical models
Scanning
Radiation
X rays

ASJC Scopus subject areas

  • Materials Science(all)
  • Engineering(all)

Cite this

The Mathematical Model of Image, Generated by Scanning Digital Radiography System. / Udod, V. A.; Osipov, S. P.; Wang, Yanzhao.

In: IOP Conference Series: Materials Science and Engineering, Vol. 168, No. 1, 012042, 07.02.2017.

Research output: Contribution to journalArticle

@article{448d5692df0a41df984c10de1bea92d6,
title = "The Mathematical Model of Image, Generated by Scanning Digital Radiography System",
abstract = "The mathematical model of image, generated by scanning digital radiography system is present. This model takes into account the X-ray energy spectrum transformation of the test object and a noise due to the quantum nature of radiation. The calculation results confirm the importance of fluctuations of the absorbed energy of the registered photon for the small size of the scintillation detectors.",
author = "Udod, {V. A.} and Osipov, {S. P.} and Yanzhao Wang",
year = "2017",
month = "2",
day = "7",
doi = "10.1088/1757-899X/168/1/012042",
language = "English",
volume = "168",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - The Mathematical Model of Image, Generated by Scanning Digital Radiography System

AU - Udod, V. A.

AU - Osipov, S. P.

AU - Wang, Yanzhao

PY - 2017/2/7

Y1 - 2017/2/7

N2 - The mathematical model of image, generated by scanning digital radiography system is present. This model takes into account the X-ray energy spectrum transformation of the test object and a noise due to the quantum nature of radiation. The calculation results confirm the importance of fluctuations of the absorbed energy of the registered photon for the small size of the scintillation detectors.

AB - The mathematical model of image, generated by scanning digital radiography system is present. This model takes into account the X-ray energy spectrum transformation of the test object and a noise due to the quantum nature of radiation. The calculation results confirm the importance of fluctuations of the absorbed energy of the registered photon for the small size of the scintillation detectors.

UR - http://www.scopus.com/inward/record.url?scp=85014489220&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85014489220&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/168/1/012042

DO - 10.1088/1757-899X/168/1/012042

M3 - Article

VL - 168

JO - IOP Conference Series: Materials Science and Engineering

JF - IOP Conference Series: Materials Science and Engineering

SN - 1757-8981

IS - 1

M1 - 012042

ER -