The influence of thermal electric power station emissions on the atmosphere of the city

Elena Faustova, Nikolai Chulkov

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Abstract

    Concentration of harmful substances in an atmosphere of Seversk town, in particular nitrogen oxides, is higher than maximum concentration limit. So, it is necessary to supervise the presence of the substances in the air and find out it's sources. Automatic station ACK3A-AM-62 is used for monitoring of atmosphere pollution. The station provides automatic measurement, processing, registration and transfer of measurement results of seven polluting substances concentration, four meteorological parameters and selection tests of a dust for the analysis of the metal content. Received parameters of the concentration of substances in the atmosphere and meteorological data are saved on a hard disk of the personal computer in a digital form, where they are worked up by a program. Using this program it is possible to carry out testing of primaries and calibration of devices. As a result of the analysis of station activity we can see the dependence of concentration NO2 upon a direction of a wind.

    Original languageEnglish
    Title of host publicationProceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology
    PublisherInstitute of Electrical and Electronics Engineers Inc.
    Pages161-163
    Number of pages3
    Volume4
    ISBN (Print)8978686206, 9788978686204
    Publication statusPublished - 2003
    Event7th Korea-Russia International Symposium on Science and Technology, KORUS 2003 - Ulsan, Korea, Republic of
    Duration: 28 Jun 20036 Jul 2003

    Other

    Other7th Korea-Russia International Symposium on Science and Technology, KORUS 2003
    CountryKorea, Republic of
    CityUlsan
    Period28.6.036.7.03

    Fingerprint

    Atmosphere
    Hot Temperature
    results measurement
    Hard disk storage
    Nitrogen oxides
    PC
    Personal computers
    Nitrogen Oxides
    Dust
    Pollution
    town
    air
    Microcomputers
    Calibration
    monitoring
    Monitoring
    Testing
    Processing
    Air
    Metals

    Keywords

    • Automatic station
    • Concentration of nitrogen dioxide
    • Gas analyser
    • Harmful substances

    ASJC Scopus subject areas

    • Building and Construction
    • Pollution
    • Biotechnology
    • Social Sciences (miscellaneous)
    • Medicine (miscellaneous)
    • Education

    Cite this

    Faustova, E., & Chulkov, N. (2003). The influence of thermal electric power station emissions on the atmosphere of the city. In Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology (Vol. 4, pp. 161-163). [1222911] Institute of Electrical and Electronics Engineers Inc..

    The influence of thermal electric power station emissions on the atmosphere of the city. / Faustova, Elena; Chulkov, Nikolai.

    Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. Vol. 4 Institute of Electrical and Electronics Engineers Inc., 2003. p. 161-163 1222911.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Faustova, E & Chulkov, N 2003, The influence of thermal electric power station emissions on the atmosphere of the city. in Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. vol. 4, 1222911, Institute of Electrical and Electronics Engineers Inc., pp. 161-163, 7th Korea-Russia International Symposium on Science and Technology, KORUS 2003, Ulsan, Korea, Republic of, 28.6.03.
    Faustova E, Chulkov N. The influence of thermal electric power station emissions on the atmosphere of the city. In Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. Vol. 4. Institute of Electrical and Electronics Engineers Inc. 2003. p. 161-163. 1222911
    Faustova, Elena ; Chulkov, Nikolai. / The influence of thermal electric power station emissions on the atmosphere of the city. Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. Vol. 4 Institute of Electrical and Electronics Engineers Inc., 2003. pp. 161-163
    @inproceedings{f4dbc5759f6648bbb2479c8c384a7694,
    title = "The influence of thermal electric power station emissions on the atmosphere of the city",
    abstract = "Concentration of harmful substances in an atmosphere of Seversk town, in particular nitrogen oxides, is higher than maximum concentration limit. So, it is necessary to supervise the presence of the substances in the air and find out it's sources. Automatic station ACK3A-AM-62 is used for monitoring of atmosphere pollution. The station provides automatic measurement, processing, registration and transfer of measurement results of seven polluting substances concentration, four meteorological parameters and selection tests of a dust for the analysis of the metal content. Received parameters of the concentration of substances in the atmosphere and meteorological data are saved on a hard disk of the personal computer in a digital form, where they are worked up by a program. Using this program it is possible to carry out testing of primaries and calibration of devices. As a result of the analysis of station activity we can see the dependence of concentration NO2 upon a direction of a wind.",
    keywords = "Automatic station, Concentration of nitrogen dioxide, Gas analyser, Harmful substances",
    author = "Elena Faustova and Nikolai Chulkov",
    year = "2003",
    language = "English",
    isbn = "8978686206",
    volume = "4",
    pages = "161--163",
    booktitle = "Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology",
    publisher = "Institute of Electrical and Electronics Engineers Inc.",

    }

    TY - GEN

    T1 - The influence of thermal electric power station emissions on the atmosphere of the city

    AU - Faustova, Elena

    AU - Chulkov, Nikolai

    PY - 2003

    Y1 - 2003

    N2 - Concentration of harmful substances in an atmosphere of Seversk town, in particular nitrogen oxides, is higher than maximum concentration limit. So, it is necessary to supervise the presence of the substances in the air and find out it's sources. Automatic station ACK3A-AM-62 is used for monitoring of atmosphere pollution. The station provides automatic measurement, processing, registration and transfer of measurement results of seven polluting substances concentration, four meteorological parameters and selection tests of a dust for the analysis of the metal content. Received parameters of the concentration of substances in the atmosphere and meteorological data are saved on a hard disk of the personal computer in a digital form, where they are worked up by a program. Using this program it is possible to carry out testing of primaries and calibration of devices. As a result of the analysis of station activity we can see the dependence of concentration NO2 upon a direction of a wind.

    AB - Concentration of harmful substances in an atmosphere of Seversk town, in particular nitrogen oxides, is higher than maximum concentration limit. So, it is necessary to supervise the presence of the substances in the air and find out it's sources. Automatic station ACK3A-AM-62 is used for monitoring of atmosphere pollution. The station provides automatic measurement, processing, registration and transfer of measurement results of seven polluting substances concentration, four meteorological parameters and selection tests of a dust for the analysis of the metal content. Received parameters of the concentration of substances in the atmosphere and meteorological data are saved on a hard disk of the personal computer in a digital form, where they are worked up by a program. Using this program it is possible to carry out testing of primaries and calibration of devices. As a result of the analysis of station activity we can see the dependence of concentration NO2 upon a direction of a wind.

    KW - Automatic station

    KW - Concentration of nitrogen dioxide

    KW - Gas analyser

    KW - Harmful substances

    UR - http://www.scopus.com/inward/record.url?scp=84944323908&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84944323908&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:84944323908

    SN - 8978686206

    SN - 9788978686204

    VL - 4

    SP - 161

    EP - 163

    BT - Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology

    PB - Institute of Electrical and Electronics Engineers Inc.

    ER -