Abstract
The effect of a local bulk flaw has been preliminary studied using a multisensory control system based on the phenomenon of mechanoelectrical transformations in dielectric structures. A hole with a variable depth served as a bulk flaw. The high efficiency of the multisensory system, which allows reliable recording of small local bulk flaws is demonstrated.
Original language | English |
---|---|
Pages (from-to) | 85-89 |
Number of pages | 5 |
Journal | Russian Journal of Nondestructive Testing |
Volume | 48 |
Issue number | 2 |
DOIs | |
Publication status | Published - Feb 2012 |
Keywords
- Bulk flaw
- Dielectric structure
- Mechanoelectric transformations
- Multisensory system
- Testing
ASJC Scopus subject areas
- Mechanical Engineering
- Mechanics of Materials
- Condensed Matter Physics