The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine

A. P. Potylitsyn, Yu A. Popov, A. V. Vukolov, I. V. Zaitsev, A. R. Wagner, V. N. Zabaev

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

With progress of accelerator and computer techniques a question about using of the monochromatic X-ray sources for medicine diagnostic purposes becomes more and more actual. In principle the monochromatic X-ray radiation may be generated using X-ray tube and crystal-monochromator. Nevertheless even using modern X-ray tubes with rotating anode it is impossible to generate the flux density of monochromatic radiation of required intensity.

Original languageEnglish
Title of host publicationRuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference
Pages203-205
Number of pages3
Publication statusPublished - 2008
Event21st Russian Particle Accelerator Conference, RuPAC 2008 - Zvenigorod, Moscow, Russian Federation
Duration: 28 Sep 20083 Oct 2008

Other

Other21st Russian Particle Accelerator Conference, RuPAC 2008
CountryRussian Federation
CityZvenigorod, Moscow
Period28.9.083.10.08

Fingerprint

medicine
tubes
x rays
computer techniques
monochromatic radiation
monochromators
anodes
accelerators
flux density
radiation
crystals

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Potylitsyn, A. P., Popov, Y. A., Vukolov, A. V., Zaitsev, I. V., Wagner, A. R., & Zabaev, V. N. (2008). The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine. In RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference (pp. 203-205)

The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine. / Potylitsyn, A. P.; Popov, Yu A.; Vukolov, A. V.; Zaitsev, I. V.; Wagner, A. R.; Zabaev, V. N.

RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference. 2008. p. 203-205.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Potylitsyn, AP, Popov, YA, Vukolov, AV, Zaitsev, IV, Wagner, AR & Zabaev, VN 2008, The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine. in RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference. pp. 203-205, 21st Russian Particle Accelerator Conference, RuPAC 2008, Zvenigorod, Moscow, Russian Federation, 28.9.08.
Potylitsyn AP, Popov YA, Vukolov AV, Zaitsev IV, Wagner AR, Zabaev VN. The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine. In RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference. 2008. p. 203-205
Potylitsyn, A. P. ; Popov, Yu A. ; Vukolov, A. V. ; Zaitsev, I. V. ; Wagner, A. R. ; Zabaev, V. N. / The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine. RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference. 2008. pp. 203-205
@inproceedings{e843d3397f7c489185a659dfe11b6f5a,
title = "The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine",
abstract = "With progress of accelerator and computer techniques a question about using of the monochromatic X-ray sources for medicine diagnostic purposes becomes more and more actual. In principle the monochromatic X-ray radiation may be generated using X-ray tube and crystal-monochromator. Nevertheless even using modern X-ray tubes with rotating anode it is impossible to generate the flux density of monochromatic radiation of required intensity.",
author = "Potylitsyn, {A. P.} and Popov, {Yu A.} and Vukolov, {A. V.} and Zaitsev, {I. V.} and Wagner, {A. R.} and Zabaev, {V. N.}",
year = "2008",
language = "English",
pages = "203--205",
booktitle = "RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference",

}

TY - GEN

T1 - The comparison of monochromatic X-ray sources based on X-ray tube and 5 MeV microtron for possible application in medicine

AU - Potylitsyn, A. P.

AU - Popov, Yu A.

AU - Vukolov, A. V.

AU - Zaitsev, I. V.

AU - Wagner, A. R.

AU - Zabaev, V. N.

PY - 2008

Y1 - 2008

N2 - With progress of accelerator and computer techniques a question about using of the monochromatic X-ray sources for medicine diagnostic purposes becomes more and more actual. In principle the monochromatic X-ray radiation may be generated using X-ray tube and crystal-monochromator. Nevertheless even using modern X-ray tubes with rotating anode it is impossible to generate the flux density of monochromatic radiation of required intensity.

AB - With progress of accelerator and computer techniques a question about using of the monochromatic X-ray sources for medicine diagnostic purposes becomes more and more actual. In principle the monochromatic X-ray radiation may be generated using X-ray tube and crystal-monochromator. Nevertheless even using modern X-ray tubes with rotating anode it is impossible to generate the flux density of monochromatic radiation of required intensity.

UR - http://www.scopus.com/inward/record.url?scp=84890094841&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890094841&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84890094841

SP - 203

EP - 205

BT - RuPAC 2008 Contributions to the Proceedings - 21st Russian Particle Accelerator Conference

ER -