The capacitive magnetic field sensor

D. O. Zyatkov, A. V. Yurchenko, V. B. Balashov, V. I. Yurchenko

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

The results of a study of sensitive element magnetic field sensor are represented in this paper. The sensor is based on the change of the capacitance with an active dielectric (ferrofluid) due to the magnitude of magnetic field. To prepare the ferrofluid magnetic particles are used, which have a followingdispersion equal to 50 <≤ <56, 45 <≤ <50, 40 <≤ <45 and ≤ <40micron of nanocrystalline alloy of brand 5BDSR. The dependence of the sensitivity of the capacitive element from the ferrofluid with different dispersion of magnetic particles is considered. The threshold of sensitivity and sensitivity of a measuring cell with ferrofluid by a magnetic field was determined. The experimental graphs of capacitance change of the magnitude of magnetic field are presented.

Original languageEnglish
Article number012065
JournalJournal of Physics: Conference Series
Volume671
Issue number1
DOIs
Publication statusPublished - 18 Jan 2016

Fingerprint

ferrofluids
sensors
magnetic fields
capacitance
sensitivity
thresholds

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

The capacitive magnetic field sensor. / Zyatkov, D. O.; Yurchenko, A. V.; Balashov, V. B.; Yurchenko, V. I.

In: Journal of Physics: Conference Series, Vol. 671, No. 1, 012065, 18.01.2016.

Research output: Contribution to journalArticle

Zyatkov, D. O. ; Yurchenko, A. V. ; Balashov, V. B. ; Yurchenko, V. I. / The capacitive magnetic field sensor. In: Journal of Physics: Conference Series. 2016 ; Vol. 671, No. 1.
@article{30e17ad28dbb4e12aee6596ea9337943,
title = "The capacitive magnetic field sensor",
abstract = "The results of a study of sensitive element magnetic field sensor are represented in this paper. The sensor is based on the change of the capacitance with an active dielectric (ferrofluid) due to the magnitude of magnetic field. To prepare the ferrofluid magnetic particles are used, which have a followingdispersion equal to 50 <≤ <56, 45 <≤ <50, 40 <≤ <45 and ≤ <40micron of nanocrystalline alloy of brand 5BDSR. The dependence of the sensitivity of the capacitive element from the ferrofluid with different dispersion of magnetic particles is considered. The threshold of sensitivity and sensitivity of a measuring cell with ferrofluid by a magnetic field was determined. The experimental graphs of capacitance change of the magnitude of magnetic field are presented.",
author = "Zyatkov, {D. O.} and Yurchenko, {A. V.} and Balashov, {V. B.} and Yurchenko, {V. I.}",
year = "2016",
month = "1",
day = "18",
doi = "10.1088/1742-6596/671/1/012065",
language = "English",
volume = "671",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - The capacitive magnetic field sensor

AU - Zyatkov, D. O.

AU - Yurchenko, A. V.

AU - Balashov, V. B.

AU - Yurchenko, V. I.

PY - 2016/1/18

Y1 - 2016/1/18

N2 - The results of a study of sensitive element magnetic field sensor are represented in this paper. The sensor is based on the change of the capacitance with an active dielectric (ferrofluid) due to the magnitude of magnetic field. To prepare the ferrofluid magnetic particles are used, which have a followingdispersion equal to 50 <≤ <56, 45 <≤ <50, 40 <≤ <45 and ≤ <40micron of nanocrystalline alloy of brand 5BDSR. The dependence of the sensitivity of the capacitive element from the ferrofluid with different dispersion of magnetic particles is considered. The threshold of sensitivity and sensitivity of a measuring cell with ferrofluid by a magnetic field was determined. The experimental graphs of capacitance change of the magnitude of magnetic field are presented.

AB - The results of a study of sensitive element magnetic field sensor are represented in this paper. The sensor is based on the change of the capacitance with an active dielectric (ferrofluid) due to the magnitude of magnetic field. To prepare the ferrofluid magnetic particles are used, which have a followingdispersion equal to 50 <≤ <56, 45 <≤ <50, 40 <≤ <45 and ≤ <40micron of nanocrystalline alloy of brand 5BDSR. The dependence of the sensitivity of the capacitive element from the ferrofluid with different dispersion of magnetic particles is considered. The threshold of sensitivity and sensitivity of a measuring cell with ferrofluid by a magnetic field was determined. The experimental graphs of capacitance change of the magnitude of magnetic field are presented.

UR - http://www.scopus.com/inward/record.url?scp=84960155715&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84960155715&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/671/1/012065

DO - 10.1088/1742-6596/671/1/012065

M3 - Article

AN - SCOPUS:84960155715

VL - 671

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012065