Hardware and functional possibilities are described of a system for control and stabilization of parameters of the photometric channels of Cherenkov detectors of extensive air showers. Results of system operation in complex climatic weather conditions are described. It is shown that the system provides for prolonged stability of parameters of amplitude-measuring channels in the limits of 2% and the accuracy of time interval measurements of 0.2 ns. It is noted that at present the parameter monitoring requires about 10% of data acquisition time.

Original languageEnglish
Pages (from-to)56-67
Number of pages12
JournalPribory i Tekhnika Eksperimenta
Issue number2
Publication statusPublished - Mar 1995

Fingerprint

cosmic ray showers
Time measurement
Data acquisition
Stabilization
stabilization
Detectors
Hardware
Monitoring
detectors
Air
weather
data acquisition
hardware
intervals

ASJC Scopus subject areas

  • Instrumentation

Cite this

System for the parameter control and stabilization of a Cherenkov detector of extensive air showers. / Bryanskij, S. V.; Vasil'chenko, Yu V.; Dudkin, G. N.; Egorov, V. Yu; Zhavoronkov, N. A.; Padalko, V. N.

In: Pribory i Tekhnika Eksperimenta, No. 2, 03.1995, p. 56-67.

Research output: Contribution to journalArticle

Bryanskij, S. V. ; Vasil'chenko, Yu V. ; Dudkin, G. N. ; Egorov, V. Yu ; Zhavoronkov, N. A. ; Padalko, V. N. / System for the parameter control and stabilization of a Cherenkov detector of extensive air showers. In: Pribory i Tekhnika Eksperimenta. 1995 ; No. 2. pp. 56-67.
@article{3b69e473f6b847a49684ca465a7aea07,
title = "System for the parameter control and stabilization of a Cherenkov detector of extensive air showers",
abstract = "Hardware and functional possibilities are described of a system for control and stabilization of parameters of the photometric channels of Cherenkov detectors of extensive air showers. Results of system operation in complex climatic weather conditions are described. It is shown that the system provides for prolonged stability of parameters of amplitude-measuring channels in the limits of 2{\%} and the accuracy of time interval measurements of 0.2 ns. It is noted that at present the parameter monitoring requires about 10{\%} of data acquisition time.",
author = "Bryanskij, {S. V.} and Vasil'chenko, {Yu V.} and Dudkin, {G. N.} and Egorov, {V. Yu} and Zhavoronkov, {N. A.} and Padalko, {V. N.}",
year = "1995",
month = "3",
language = "English",
pages = "56--67",
journal = "Pribory i Tekhnika Eksperimenta",
issn = "0032-8162",
publisher = "Izdatel'stvo Nauka",
number = "2",

}

TY - JOUR

T1 - System for the parameter control and stabilization of a Cherenkov detector of extensive air showers

AU - Bryanskij, S. V.

AU - Vasil'chenko, Yu V.

AU - Dudkin, G. N.

AU - Egorov, V. Yu

AU - Zhavoronkov, N. A.

AU - Padalko, V. N.

PY - 1995/3

Y1 - 1995/3

N2 - Hardware and functional possibilities are described of a system for control and stabilization of parameters of the photometric channels of Cherenkov detectors of extensive air showers. Results of system operation in complex climatic weather conditions are described. It is shown that the system provides for prolonged stability of parameters of amplitude-measuring channels in the limits of 2% and the accuracy of time interval measurements of 0.2 ns. It is noted that at present the parameter monitoring requires about 10% of data acquisition time.

AB - Hardware and functional possibilities are described of a system for control and stabilization of parameters of the photometric channels of Cherenkov detectors of extensive air showers. Results of system operation in complex climatic weather conditions are described. It is shown that the system provides for prolonged stability of parameters of amplitude-measuring channels in the limits of 2% and the accuracy of time interval measurements of 0.2 ns. It is noted that at present the parameter monitoring requires about 10% of data acquisition time.

UR - http://www.scopus.com/inward/record.url?scp=0029259546&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029259546&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0029259546

SP - 56

EP - 67

JO - Pribory i Tekhnika Eksperimenta

JF - Pribory i Tekhnika Eksperimenta

SN - 0032-8162

IS - 2

ER -