Synthesis and characterization of TiSiON biocompatible thin films used in biomedical applications

Cosmin M. Cotrut, Catalin Vitelaru, Mihaela Dinu, Tudor Petreus, Alina Vladescu

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The main aim of the present work was to prepare and investigate TiSiON coatings as possible candidates for biomedical applications. The coatings were obtained by the cathodic arc method at different substrate bias voltages in a reactive atmosphere, N2 and O2 gas mixture. Various film properties (elemental and phase composition, texture, hardness, adhesion, corrosion resistance, friction behaviour, biological performance) and their dependence on the substrate bias were determined. The possible use of TiSiON coatings for improving the adhesion between the dental ceramic and metallic substrate in dental restorations has been analysed and discussed.

Original languageEnglish
Pages (from-to)1351-1360
Number of pages10
JournalScience of Advanced Materials
Volume7
Issue number7
DOIs
Publication statusPublished - 1 Jan 2015
Externally publishedYes

Fingerprint

Thin films
Coatings
Substrates
Adhesion
Bias voltage
Phase composition
Gas mixtures
Restoration
Corrosion resistance
Textures
Hardness
Friction

Keywords

  • Biological properties
  • Cathodic arc
  • Corrosion resistance
  • TiSiON films

ASJC Scopus subject areas

  • Materials Science(all)

Cite this

Synthesis and characterization of TiSiON biocompatible thin films used in biomedical applications. / Cotrut, Cosmin M.; Vitelaru, Catalin; Dinu, Mihaela; Petreus, Tudor; Vladescu, Alina.

In: Science of Advanced Materials, Vol. 7, No. 7, 01.01.2015, p. 1351-1360.

Research output: Contribution to journalArticle

@article{df76baa2e90a4e1abf47bc002b7469eb,
title = "Synthesis and characterization of TiSiON biocompatible thin films used in biomedical applications",
abstract = "The main aim of the present work was to prepare and investigate TiSiON coatings as possible candidates for biomedical applications. The coatings were obtained by the cathodic arc method at different substrate bias voltages in a reactive atmosphere, N2 and O2 gas mixture. Various film properties (elemental and phase composition, texture, hardness, adhesion, corrosion resistance, friction behaviour, biological performance) and their dependence on the substrate bias were determined. The possible use of TiSiON coatings for improving the adhesion between the dental ceramic and metallic substrate in dental restorations has been analysed and discussed.",
keywords = "Biological properties, Cathodic arc, Corrosion resistance, TiSiON films",
author = "Cotrut, {Cosmin M.} and Catalin Vitelaru and Mihaela Dinu and Tudor Petreus and Alina Vladescu",
year = "2015",
month = "1",
day = "1",
doi = "10.1166/sam.2015.2051",
language = "English",
volume = "7",
pages = "1351--1360",
journal = "Science of Advanced Materials",
issn = "1947-2935",
publisher = "American Scientific Publishers",
number = "7",

}

TY - JOUR

T1 - Synthesis and characterization of TiSiON biocompatible thin films used in biomedical applications

AU - Cotrut, Cosmin M.

AU - Vitelaru, Catalin

AU - Dinu, Mihaela

AU - Petreus, Tudor

AU - Vladescu, Alina

PY - 2015/1/1

Y1 - 2015/1/1

N2 - The main aim of the present work was to prepare and investigate TiSiON coatings as possible candidates for biomedical applications. The coatings were obtained by the cathodic arc method at different substrate bias voltages in a reactive atmosphere, N2 and O2 gas mixture. Various film properties (elemental and phase composition, texture, hardness, adhesion, corrosion resistance, friction behaviour, biological performance) and their dependence on the substrate bias were determined. The possible use of TiSiON coatings for improving the adhesion between the dental ceramic and metallic substrate in dental restorations has been analysed and discussed.

AB - The main aim of the present work was to prepare and investigate TiSiON coatings as possible candidates for biomedical applications. The coatings were obtained by the cathodic arc method at different substrate bias voltages in a reactive atmosphere, N2 and O2 gas mixture. Various film properties (elemental and phase composition, texture, hardness, adhesion, corrosion resistance, friction behaviour, biological performance) and their dependence on the substrate bias were determined. The possible use of TiSiON coatings for improving the adhesion between the dental ceramic and metallic substrate in dental restorations has been analysed and discussed.

KW - Biological properties

KW - Cathodic arc

KW - Corrosion resistance

KW - TiSiON films

UR - http://www.scopus.com/inward/record.url?scp=84922194766&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84922194766&partnerID=8YFLogxK

U2 - 10.1166/sam.2015.2051

DO - 10.1166/sam.2015.2051

M3 - Article

AN - SCOPUS:84922194766

VL - 7

SP - 1351

EP - 1360

JO - Science of Advanced Materials

JF - Science of Advanced Materials

SN - 1947-2935

IS - 7

ER -