Sub-millimeter bunch length non-invasive diagnostic based on the diffraction and Cherenkov radiation

Research output: Contribution to journalConference article

5 Citations (Scopus)

Abstract

A layout for the investigation the coherent Cherenkov radiation from a dielectric target with a large spectral dispersion and the coherent diffraction radiation from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics are proposed for the 20∼30MeV Linac at Shanghai Institute of Applied Physics (SINAP). In this paper the status of the joint experiment and future plans are presented.

Original languageEnglish
Article number012023
JournalJournal of Physics: Conference Series
Volume357
Issue number1
DOIs
Publication statusPublished - 1 Jan 2012
Event9th International Symposium on Radiation from Relativistic Electrons in Periodic Structures, RREPS-2011 - Egham, United Kingdom
Duration: 12 Sep 201116 Sep 2011

Fingerprint

diffraction radiation
coherent radiation
layouts
electron beams
conduction
physics
radiation
profiles

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

@article{49b87864cc714663bb470181d62cfe8d,
title = "Sub-millimeter bunch length non-invasive diagnostic based on the diffraction and Cherenkov radiation",
abstract = "A layout for the investigation the coherent Cherenkov radiation from a dielectric target with a large spectral dispersion and the coherent diffraction radiation from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics are proposed for the 20∼30MeV Linac at Shanghai Institute of Applied Physics (SINAP). In this paper the status of the joint experiment and future plans are presented.",
author = "M. Shevelev and H. Deng and A. Potylitsyn and G. Naumenko and J. Zhang and Sh Lu and Gogolev, {Sergey Yurtievich} and D. Shkitov",
year = "2012",
month = "1",
day = "1",
doi = "10.1088/1742-6596/357/1/012023",
language = "English",
volume = "357",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Sub-millimeter bunch length non-invasive diagnostic based on the diffraction and Cherenkov radiation

AU - Shevelev, M.

AU - Deng, H.

AU - Potylitsyn, A.

AU - Naumenko, G.

AU - Zhang, J.

AU - Lu, Sh

AU - Gogolev, Sergey Yurtievich

AU - Shkitov, D.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - A layout for the investigation the coherent Cherenkov radiation from a dielectric target with a large spectral dispersion and the coherent diffraction radiation from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics are proposed for the 20∼30MeV Linac at Shanghai Institute of Applied Physics (SINAP). In this paper the status of the joint experiment and future plans are presented.

AB - A layout for the investigation the coherent Cherenkov radiation from a dielectric target with a large spectral dispersion and the coherent diffraction radiation from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics are proposed for the 20∼30MeV Linac at Shanghai Institute of Applied Physics (SINAP). In this paper the status of the joint experiment and future plans are presented.

UR - http://www.scopus.com/inward/record.url?scp=84862085574&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84862085574&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/357/1/012023

DO - 10.1088/1742-6596/357/1/012023

M3 - Conference article

AN - SCOPUS:84862085574

VL - 357

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012023

ER -