Abstract

Temperature distribution in samples during high-doze ion implantation (HDII) was studied theoretically and experimentally. By means of electron microscope investigation, a necessity was found to keep temperature regime of sample tempering in order to retain initial martensite structure of ShH-15 steel samples after HDII. Main parameter responsible for irradiation temperature regime was determined to be average current density. Dependencies of sample temperature under HDII on exposition doze are determined theoretically and experimentally. Optimal regimes for martensite steels irradiation using pulse-periodic implanters of DIANA type under ion energy of 100 keV and absence of special heat removal are the following parameters: jr (ion current density in pulse) = 0.1 mA/cm2 and ν (pulse repetition frequency) = 50 s-1 or jr=0.2 mA/cm2 and ν=25 s-1.

Original languageEnglish
Pages (from-to)22-27
Number of pages6
JournalFizika i Khimiya Obrabotki Materialov
Issue number4
Publication statusPublished - Jul 1992
Externally publishedYes

Fingerprint

Martensitic steel
Ion implantation
Steel
Martensite
Current density
Irradiation
Ions
Tempering
Temperature
Temperature distribution
Electron microscopes

ASJC Scopus subject areas

  • Materials Science(all)

Cite this

Study of martensitic steels temperature regimes under high doze ion implantation. / Abdrashitov, V. G.; Ryzhov, V. V.; Sergeev, Victor Petrovich; Yanovskij, V. P.

In: Fizika i Khimiya Obrabotki Materialov, No. 4, 07.1992, p. 22-27.

Research output: Contribution to journalArticle

@article{a58484823f6645a185cab16098cbe852,
title = "Study of martensitic steels temperature regimes under high doze ion implantation",
abstract = "Temperature distribution in samples during high-doze ion implantation (HDII) was studied theoretically and experimentally. By means of electron microscope investigation, a necessity was found to keep temperature regime of sample tempering in order to retain initial martensite structure of ShH-15 steel samples after HDII. Main parameter responsible for irradiation temperature regime was determined to be average current density. Dependencies of sample temperature under HDII on exposition doze are determined theoretically and experimentally. Optimal regimes for martensite steels irradiation using pulse-periodic implanters of DIANA type under ion energy of 100 keV and absence of special heat removal are the following parameters: jr (ion current density in pulse) = 0.1 mA/cm2 and ν (pulse repetition frequency) = 50 s-1 or jr=0.2 mA/cm2 and ν=25 s-1.",
author = "Abdrashitov, {V. G.} and Ryzhov, {V. V.} and Sergeev, {Victor Petrovich} and Yanovskij, {V. P.}",
year = "1992",
month = "7",
language = "English",
pages = "22--27",
journal = "Fizika i Khimiya Obrabotki Materialov",
issn = "0015-3214",
publisher = "Izdatel'stvo Nauka",
number = "4",

}

TY - JOUR

T1 - Study of martensitic steels temperature regimes under high doze ion implantation

AU - Abdrashitov, V. G.

AU - Ryzhov, V. V.

AU - Sergeev, Victor Petrovich

AU - Yanovskij, V. P.

PY - 1992/7

Y1 - 1992/7

N2 - Temperature distribution in samples during high-doze ion implantation (HDII) was studied theoretically and experimentally. By means of electron microscope investigation, a necessity was found to keep temperature regime of sample tempering in order to retain initial martensite structure of ShH-15 steel samples after HDII. Main parameter responsible for irradiation temperature regime was determined to be average current density. Dependencies of sample temperature under HDII on exposition doze are determined theoretically and experimentally. Optimal regimes for martensite steels irradiation using pulse-periodic implanters of DIANA type under ion energy of 100 keV and absence of special heat removal are the following parameters: jr (ion current density in pulse) = 0.1 mA/cm2 and ν (pulse repetition frequency) = 50 s-1 or jr=0.2 mA/cm2 and ν=25 s-1.

AB - Temperature distribution in samples during high-doze ion implantation (HDII) was studied theoretically and experimentally. By means of electron microscope investigation, a necessity was found to keep temperature regime of sample tempering in order to retain initial martensite structure of ShH-15 steel samples after HDII. Main parameter responsible for irradiation temperature regime was determined to be average current density. Dependencies of sample temperature under HDII on exposition doze are determined theoretically and experimentally. Optimal regimes for martensite steels irradiation using pulse-periodic implanters of DIANA type under ion energy of 100 keV and absence of special heat removal are the following parameters: jr (ion current density in pulse) = 0.1 mA/cm2 and ν (pulse repetition frequency) = 50 s-1 or jr=0.2 mA/cm2 and ν=25 s-1.

UR - http://www.scopus.com/inward/record.url?scp=0026884534&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026884534&partnerID=8YFLogxK

M3 - Article

SP - 22

EP - 27

JO - Fizika i Khimiya Obrabotki Materialov

JF - Fizika i Khimiya Obrabotki Materialov

SN - 0015-3214

IS - 4

ER -