Stabilnost ručnog elektrolučnog zavarivanja na zaštitnim prevlakama

Translated title of the contribution: Stability of MMA welding with protective coatings

Dmitry P. Ilyashchenko, Dmitry A. Chinakhov, Elena V. Verkhoturova, Elena V. Lavrova

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

The paper presents outcomes of comprehensive research that examines the relevance of protective surface coatings on a product to be welded for such parameters as MMA welding stability, width of temperature fields on the surface of a welded structure, as well as structure and phase composition of the deposited metal. The experimental study has associated the use of a protective coating in MMA with an increase in certain characteristics - shortcut period of arc gap (5-11 %); bridging time (10-12 %); mass of transferred electrode metal droplets (up to 50 %); amplitude value of the welding current (25 %); size of a deposited metal grain; and a heat affected zone (15-25%).

Translated title of the contributionStability of MMA welding with protective coatings
Original languageBosnian
Pages (from-to)33-36
Number of pages4
JournalStructural Integrity and Life
Volume20
Issue number1
Publication statusPublished - 2020

Keywords

  • Arc stability welding
  • Heat content
  • Manual arc welding
  • Microstructure
  • Protective coating
  • Weld pool

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Safety, Risk, Reliability and Quality
  • Mechanics of Materials
  • Metals and Alloys

Fingerprint Dive into the research topics of 'Stability of MMA welding with protective coatings'. Together they form a unique fingerprint.