Abstract
Fixed multigap spark discharger has been designed capable of switching currents of up to 100 kamp and having switching-time spread of less than 5 nsec in voltage range from 8 to 50 kv; this allows discharger to be connected for parallel operation of high- power capacitor banks without need of decoupling devices.
Original language | English |
---|---|
Title of host publication | Instruments & Experimental Techniques (English translation of Pribory i Tekhnika Eksperimenta) |
Pages | 1452-1454 |
Number of pages | 3 |
Edition | 6 |
Publication status | Published - Nov 1968 |
ASJC Scopus subject areas
- Engineering(all)