Abstract

The paper describes the algorithm of reconstruction of tomographic image used in the through-transition method in a small angle sounding of acoustic linear arrays and the results of practical application of the proposed algorithm. In alternate probing of each element of emitting array and simultaneous reception of all elements of the receiving array is a collection of shadow images of the testing zone. The testing zone is divided into small local areas and using the collection of shadow images computed matrix normalized transmission coefficients for each of the small local area. Tomographic image control zone is obtained by submitting the resulting matrix of normalized transmission coefficients in grayscale or colors.

Original languageEnglish
Title of host publicationMATEC Web of Conferences
PublisherEDP Sciences
Volume48
DOIs
Publication statusPublished - 4 Apr 2016
Event4th Russian Forum for Young Scientists with International Participation "Space Engineering" 2016 - Tomsk, Russian Federation
Duration: 12 Apr 201614 Apr 2016

Other

Other4th Russian Forum for Young Scientists with International Participation "Space Engineering" 2016
CountryRussian Federation
CityTomsk
Period12.4.1614.4.16

Fingerprint

Tomography
Inspection
Acoustics
Testing
Color

ASJC Scopus subject areas

  • Chemistry(all)
  • Engineering(all)
  • Materials Science(all)

Cite this

Soldatov, A., Soldatov, A. A., Kostina, M., Bakanov, P., & Polonskaya, M. (2016). Small-angle tomography algorithm for transmission inspection of acoustic linear array. In MATEC Web of Conferences (Vol. 48). [03006] EDP Sciences. https://doi.org/10.1051/confmatec/20164803006

Small-angle tomography algorithm for transmission inspection of acoustic linear array. / Soldatov, Alexey; Soldatov, Andrey Alexeevich; Kostina, Masha; Bakanov, Petr; Polonskaya, Marina.

MATEC Web of Conferences. Vol. 48 EDP Sciences, 2016. 03006.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Soldatov, A, Soldatov, AA, Kostina, M, Bakanov, P & Polonskaya, M 2016, Small-angle tomography algorithm for transmission inspection of acoustic linear array. in MATEC Web of Conferences. vol. 48, 03006, EDP Sciences, 4th Russian Forum for Young Scientists with International Participation "Space Engineering" 2016, Tomsk, Russian Federation, 12.4.16. https://doi.org/10.1051/confmatec/20164803006
Soldatov A, Soldatov AA, Kostina M, Bakanov P, Polonskaya M. Small-angle tomography algorithm for transmission inspection of acoustic linear array. In MATEC Web of Conferences. Vol. 48. EDP Sciences. 2016. 03006 https://doi.org/10.1051/confmatec/20164803006
Soldatov, Alexey ; Soldatov, Andrey Alexeevich ; Kostina, Masha ; Bakanov, Petr ; Polonskaya, Marina. / Small-angle tomography algorithm for transmission inspection of acoustic linear array. MATEC Web of Conferences. Vol. 48 EDP Sciences, 2016.
@inproceedings{1d90f6cb30534f2c80d1be9c4d2fb0ce,
title = "Small-angle tomography algorithm for transmission inspection of acoustic linear array",
abstract = "The paper describes the algorithm of reconstruction of tomographic image used in the through-transition method in a small angle sounding of acoustic linear arrays and the results of practical application of the proposed algorithm. In alternate probing of each element of emitting array and simultaneous reception of all elements of the receiving array is a collection of shadow images of the testing zone. The testing zone is divided into small local areas and using the collection of shadow images computed matrix normalized transmission coefficients for each of the small local area. Tomographic image control zone is obtained by submitting the resulting matrix of normalized transmission coefficients in grayscale or colors.",
author = "Alexey Soldatov and Soldatov, {Andrey Alexeevich} and Masha Kostina and Petr Bakanov and Marina Polonskaya",
year = "2016",
month = "4",
day = "4",
doi = "10.1051/confmatec/20164803006",
language = "English",
volume = "48",
booktitle = "MATEC Web of Conferences",
publisher = "EDP Sciences",

}

TY - GEN

T1 - Small-angle tomography algorithm for transmission inspection of acoustic linear array

AU - Soldatov, Alexey

AU - Soldatov, Andrey Alexeevich

AU - Kostina, Masha

AU - Bakanov, Petr

AU - Polonskaya, Marina

PY - 2016/4/4

Y1 - 2016/4/4

N2 - The paper describes the algorithm of reconstruction of tomographic image used in the through-transition method in a small angle sounding of acoustic linear arrays and the results of practical application of the proposed algorithm. In alternate probing of each element of emitting array and simultaneous reception of all elements of the receiving array is a collection of shadow images of the testing zone. The testing zone is divided into small local areas and using the collection of shadow images computed matrix normalized transmission coefficients for each of the small local area. Tomographic image control zone is obtained by submitting the resulting matrix of normalized transmission coefficients in grayscale or colors.

AB - The paper describes the algorithm of reconstruction of tomographic image used in the through-transition method in a small angle sounding of acoustic linear arrays and the results of practical application of the proposed algorithm. In alternate probing of each element of emitting array and simultaneous reception of all elements of the receiving array is a collection of shadow images of the testing zone. The testing zone is divided into small local areas and using the collection of shadow images computed matrix normalized transmission coefficients for each of the small local area. Tomographic image control zone is obtained by submitting the resulting matrix of normalized transmission coefficients in grayscale or colors.

UR - http://www.scopus.com/inward/record.url?scp=84969988977&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84969988977&partnerID=8YFLogxK

U2 - 10.1051/confmatec/20164803006

DO - 10.1051/confmatec/20164803006

M3 - Conference contribution

VL - 48

BT - MATEC Web of Conferences

PB - EDP Sciences

ER -