Simultaneous Determination of Homovanillic and Vanillylmandelic Acid by HPLC Using a Coulometric Detector with Renewable Glassy Carbon Microbeads Based Working Electrode

Jan Mika, Jiří Barek, Jiří Zima, Josino Costa Moreira, Hana Dejmková

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Homovanilic (HVA) and vanillylmandelic (VMA) acid are catecholamines metabolites commonly used as cancer biomarkers. New method for simultaneous determination of both these metabolites is presented, using recently developed flow-through coulometric detector based on glassy carbon microbeads. This application presents the potential opportunities of the above mentioned coulometric detector for the simultaneous determination of mixture of substances in complicated matrix in combination with gradient chromatography. Optimum conditions were set as follows: mobile phase consisting of acetonitrile (eluent A) and ten time diluted B-R buffer pH 3 (eluent B) with gradient program 5 % A (2 min), 5 % A to 25 % A (8 min), 25 % A (4 min), 25 % A to 95 % A (1 min), and 95 % A (4 min); flow rate of mobile phase 0.7 mL min−1, detection potential +1.3 V, and injection volume 20 μL. Calibration dependences of both metabolites were linear from concentration 100 μmol L−1 to their quantitation limits (i.e. 0.6 μmol L−1 for HVA and 1.3 μmol L−1 for VMA, respectively). Standard addition method was applied for the determination of these analytes in human urine. Obtained results are in agreement with results of HPLC method with UV detector.

Original languageEnglish
Pages (from-to)1455-1460
Number of pages6
JournalElectroanalysis
Volume30
Issue number7
DOIs
Publication statusPublished - 1 Jul 2018
Externally publishedYes

Fingerprint

Vanilmandelic Acid
Homovanillic Acid
Glassy carbon
Metabolites
Detectors
Electrodes
Acids
Ultraviolet detectors
Tumor Biomarkers
Chromatography
Acetonitrile
Catecholamines
Buffers
Flow rate
Calibration

Keywords

  • Coulometric detection
  • Glassy carbon microbeads
  • HPLC
  • Tumor markers

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Cite this

Simultaneous Determination of Homovanillic and Vanillylmandelic Acid by HPLC Using a Coulometric Detector with Renewable Glassy Carbon Microbeads Based Working Electrode. / Mika, Jan; Barek, Jiří; Zima, Jiří; Moreira, Josino Costa; Dejmková, Hana.

In: Electroanalysis, Vol. 30, No. 7, 01.07.2018, p. 1455-1460.

Research output: Contribution to journalArticle

@article{dfbd38097bfa47dea40730d8a6995815,
title = "Simultaneous Determination of Homovanillic and Vanillylmandelic Acid by HPLC Using a Coulometric Detector with Renewable Glassy Carbon Microbeads Based Working Electrode",
abstract = "Homovanilic (HVA) and vanillylmandelic (VMA) acid are catecholamines metabolites commonly used as cancer biomarkers. New method for simultaneous determination of both these metabolites is presented, using recently developed flow-through coulometric detector based on glassy carbon microbeads. This application presents the potential opportunities of the above mentioned coulometric detector for the simultaneous determination of mixture of substances in complicated matrix in combination with gradient chromatography. Optimum conditions were set as follows: mobile phase consisting of acetonitrile (eluent A) and ten time diluted B-R buffer pH 3 (eluent B) with gradient program 5 {\%} A (2 min), 5 {\%} A to 25 {\%} A (8 min), 25 {\%} A (4 min), 25 {\%} A to 95 {\%} A (1 min), and 95 {\%} A (4 min); flow rate of mobile phase 0.7 mL min−1, detection potential +1.3 V, and injection volume 20 μL. Calibration dependences of both metabolites were linear from concentration 100 μmol L−1 to their quantitation limits (i.e. 0.6 μmol L−1 for HVA and 1.3 μmol L−1 for VMA, respectively). Standard addition method was applied for the determination of these analytes in human urine. Obtained results are in agreement with results of HPLC method with UV detector.",
keywords = "Coulometric detection, Glassy carbon microbeads, HPLC, Tumor markers",
author = "Jan Mika and Jiř{\'i} Barek and Jiř{\'i} Zima and Moreira, {Josino Costa} and Hana Dejmkov{\'a}",
year = "2018",
month = "7",
day = "1",
doi = "10.1002/elan.201800041",
language = "English",
volume = "30",
pages = "1455--1460",
journal = "Macromolecular Chemistry and Physics",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "7",

}

TY - JOUR

T1 - Simultaneous Determination of Homovanillic and Vanillylmandelic Acid by HPLC Using a Coulometric Detector with Renewable Glassy Carbon Microbeads Based Working Electrode

AU - Mika, Jan

AU - Barek, Jiří

AU - Zima, Jiří

AU - Moreira, Josino Costa

AU - Dejmková, Hana

PY - 2018/7/1

Y1 - 2018/7/1

N2 - Homovanilic (HVA) and vanillylmandelic (VMA) acid are catecholamines metabolites commonly used as cancer biomarkers. New method for simultaneous determination of both these metabolites is presented, using recently developed flow-through coulometric detector based on glassy carbon microbeads. This application presents the potential opportunities of the above mentioned coulometric detector for the simultaneous determination of mixture of substances in complicated matrix in combination with gradient chromatography. Optimum conditions were set as follows: mobile phase consisting of acetonitrile (eluent A) and ten time diluted B-R buffer pH 3 (eluent B) with gradient program 5 % A (2 min), 5 % A to 25 % A (8 min), 25 % A (4 min), 25 % A to 95 % A (1 min), and 95 % A (4 min); flow rate of mobile phase 0.7 mL min−1, detection potential +1.3 V, and injection volume 20 μL. Calibration dependences of both metabolites were linear from concentration 100 μmol L−1 to their quantitation limits (i.e. 0.6 μmol L−1 for HVA and 1.3 μmol L−1 for VMA, respectively). Standard addition method was applied for the determination of these analytes in human urine. Obtained results are in agreement with results of HPLC method with UV detector.

AB - Homovanilic (HVA) and vanillylmandelic (VMA) acid are catecholamines metabolites commonly used as cancer biomarkers. New method for simultaneous determination of both these metabolites is presented, using recently developed flow-through coulometric detector based on glassy carbon microbeads. This application presents the potential opportunities of the above mentioned coulometric detector for the simultaneous determination of mixture of substances in complicated matrix in combination with gradient chromatography. Optimum conditions were set as follows: mobile phase consisting of acetonitrile (eluent A) and ten time diluted B-R buffer pH 3 (eluent B) with gradient program 5 % A (2 min), 5 % A to 25 % A (8 min), 25 % A (4 min), 25 % A to 95 % A (1 min), and 95 % A (4 min); flow rate of mobile phase 0.7 mL min−1, detection potential +1.3 V, and injection volume 20 μL. Calibration dependences of both metabolites were linear from concentration 100 μmol L−1 to their quantitation limits (i.e. 0.6 μmol L−1 for HVA and 1.3 μmol L−1 for VMA, respectively). Standard addition method was applied for the determination of these analytes in human urine. Obtained results are in agreement with results of HPLC method with UV detector.

KW - Coulometric detection

KW - Glassy carbon microbeads

KW - HPLC

KW - Tumor markers

UR - http://www.scopus.com/inward/record.url?scp=85045103194&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85045103194&partnerID=8YFLogxK

U2 - 10.1002/elan.201800041

DO - 10.1002/elan.201800041

M3 - Article

VL - 30

SP - 1455

EP - 1460

JO - Macromolecular Chemistry and Physics

JF - Macromolecular Chemistry and Physics

SN - 1040-0397

IS - 7

ER -