Abstract
A simple construction is described for a high-voltage spark gap. The inductance of the spark gap is 5 multiplied by (times) 10** minus **9 H. Tests were carried out at a voltage of 60 to 100 kv at currents of up to 20 ka.
Original language | English |
---|---|
Pages (from-to) | 461-462 |
Number of pages | 2 |
Journal | Instrum Exp Tech |
Volume | 18 |
Issue number | 2 pt 1 |
Publication status | Published - 1975 |
ASJC Scopus subject areas
- Instrumentation