TY - JOUR
T1 - Selection of optimal reheat temperature in heat recovery boiler at combined heat and power plant with GT-topping
AU - Romashova, Olga
AU - Tubolev, Alexander
AU - Matveeva, Anastasia
AU - Zenkov, Andrey
AU - Asmolovsky, Valentin
PY - 2017/12/12
Y1 - 2017/12/12
N2 - Calculations to determine optimum value of steam reheat temperature in relation to the cycle arrangement of steam turbine power plant with gas turbine topping are conducted in this paper. Operation of T-250-240 turbine unit in cogeneration mode has been considered during steam reheat displacement from steam boiler to heat recovery boiler.
AB - Calculations to determine optimum value of steam reheat temperature in relation to the cycle arrangement of steam turbine power plant with gas turbine topping are conducted in this paper. Operation of T-250-240 turbine unit in cogeneration mode has been considered during steam reheat displacement from steam boiler to heat recovery boiler.
UR - http://www.scopus.com/inward/record.url?scp=85046362306&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85046362306&partnerID=8YFLogxK
U2 - 10.1051/matecconf/201714101029
DO - 10.1051/matecconf/201714101029
M3 - Conference article
AN - SCOPUS:85046362306
VL - 141
JO - MATEC Web of Conferences
JF - MATEC Web of Conferences
SN - 2261-236X
M1 - 01029
T2 - 5th International Youth Forum on Smart Grids 2017
Y2 - 9 October 2017 through 13 October 2017
ER -