Abstract

Issues of improving the efficiency of combined cycle gas turbines (CCGT) recovery type have been presented. Efficiency gas turbine plant reaches values of 45 % due to rise in temperature to a gas turbine to 1700 °C. Modern technologies for improving the cooling gas turbine components and reducing the excess air ratio leads to a further increase of the efficiency by 1-2 %. Based on research conducted at the Tomsk Polytechnic University, it shows that the CCGT efficiency can be increased by 2-3 % in the winter time due to the use of organic Rankine cycle, low-boiling substances, and air-cooled condensers (ACC). It is necessary to apply the waste heat recovery with condensation of water vapor from the flue gas, it will enhance the efficiency of the CCGT by 2-3 % to increase the efficiency of the heat recovery steam boiler (HRSB) to 10-12 %. Replacing electric pumps gas turbine engine (GTE) helps to reduce electricity consumption for auxiliary needs CCGT by 0.5-1.5 %. At the same time the heat of flue gas turbine engine may be useful used in HRSB, thus will increase the capacity and efficiency of the steam turbine.

Original languageEnglish
Article number01004
JournalMATEC Web of Conferences
Volume91
DOIs
Publication statusPublished - 20 Dec 2016

Fingerprint

Gas turbines
Steam
Waste heat utilization
Flue gases
Boilers
Turbines
Turbine components
Direction compound
Rankine cycle
Steam turbines
Air
Boiling liquids
Water vapor
Condensation
Electricity
Pumps
Cooling
Recovery

ASJC Scopus subject areas

  • Chemistry(all)
  • Engineering(all)
  • Materials Science(all)

Cite this

Promising Direction of Perfection of the Utilization Combine Cycle Gas Turbine Units. / Gabdullina, Albina I.; Galashov, Nikolay N.; Tsibulskiy, Svyatoslav A.; Melnikov, Denis V.; Asanov, Ilya A.; Kiselev, Alexander S.

In: MATEC Web of Conferences, Vol. 91, 01004, 20.12.2016.

Research output: Contribution to journalArticle

Gabdullina, Albina I. ; Galashov, Nikolay N. ; Tsibulskiy, Svyatoslav A. ; Melnikov, Denis V. ; Asanov, Ilya A. ; Kiselev, Alexander S. / Promising Direction of Perfection of the Utilization Combine Cycle Gas Turbine Units. In: MATEC Web of Conferences. 2016 ; Vol. 91.
@article{49f2719ae10b4054bcca53c5c84d9fb1,
title = "Promising Direction of Perfection of the Utilization Combine Cycle Gas Turbine Units",
abstract = "Issues of improving the efficiency of combined cycle gas turbines (CCGT) recovery type have been presented. Efficiency gas turbine plant reaches values of 45 {\%} due to rise in temperature to a gas turbine to 1700 °C. Modern technologies for improving the cooling gas turbine components and reducing the excess air ratio leads to a further increase of the efficiency by 1-2 {\%}. Based on research conducted at the Tomsk Polytechnic University, it shows that the CCGT efficiency can be increased by 2-3 {\%} in the winter time due to the use of organic Rankine cycle, low-boiling substances, and air-cooled condensers (ACC). It is necessary to apply the waste heat recovery with condensation of water vapor from the flue gas, it will enhance the efficiency of the CCGT by 2-3 {\%} to increase the efficiency of the heat recovery steam boiler (HRSB) to 10-12 {\%}. Replacing electric pumps gas turbine engine (GTE) helps to reduce electricity consumption for auxiliary needs CCGT by 0.5-1.5 {\%}. At the same time the heat of flue gas turbine engine may be useful used in HRSB, thus will increase the capacity and efficiency of the steam turbine.",
author = "Gabdullina, {Albina I.} and Galashov, {Nikolay N.} and Tsibulskiy, {Svyatoslav A.} and Melnikov, {Denis V.} and Asanov, {Ilya A.} and Kiselev, {Alexander S.}",
year = "2016",
month = "12",
day = "20",
doi = "10.1051/matecconf/20179101004",
language = "English",
volume = "91",
journal = "MATEC Web of Conferences",

}

TY - JOUR

T1 - Promising Direction of Perfection of the Utilization Combine Cycle Gas Turbine Units

AU - Gabdullina, Albina I.

AU - Galashov, Nikolay N.

AU - Tsibulskiy, Svyatoslav A.

AU - Melnikov, Denis V.

AU - Asanov, Ilya A.

AU - Kiselev, Alexander S.

PY - 2016/12/20

Y1 - 2016/12/20

N2 - Issues of improving the efficiency of combined cycle gas turbines (CCGT) recovery type have been presented. Efficiency gas turbine plant reaches values of 45 % due to rise in temperature to a gas turbine to 1700 °C. Modern technologies for improving the cooling gas turbine components and reducing the excess air ratio leads to a further increase of the efficiency by 1-2 %. Based on research conducted at the Tomsk Polytechnic University, it shows that the CCGT efficiency can be increased by 2-3 % in the winter time due to the use of organic Rankine cycle, low-boiling substances, and air-cooled condensers (ACC). It is necessary to apply the waste heat recovery with condensation of water vapor from the flue gas, it will enhance the efficiency of the CCGT by 2-3 % to increase the efficiency of the heat recovery steam boiler (HRSB) to 10-12 %. Replacing electric pumps gas turbine engine (GTE) helps to reduce electricity consumption for auxiliary needs CCGT by 0.5-1.5 %. At the same time the heat of flue gas turbine engine may be useful used in HRSB, thus will increase the capacity and efficiency of the steam turbine.

AB - Issues of improving the efficiency of combined cycle gas turbines (CCGT) recovery type have been presented. Efficiency gas turbine plant reaches values of 45 % due to rise in temperature to a gas turbine to 1700 °C. Modern technologies for improving the cooling gas turbine components and reducing the excess air ratio leads to a further increase of the efficiency by 1-2 %. Based on research conducted at the Tomsk Polytechnic University, it shows that the CCGT efficiency can be increased by 2-3 % in the winter time due to the use of organic Rankine cycle, low-boiling substances, and air-cooled condensers (ACC). It is necessary to apply the waste heat recovery with condensation of water vapor from the flue gas, it will enhance the efficiency of the CCGT by 2-3 % to increase the efficiency of the heat recovery steam boiler (HRSB) to 10-12 %. Replacing electric pumps gas turbine engine (GTE) helps to reduce electricity consumption for auxiliary needs CCGT by 0.5-1.5 %. At the same time the heat of flue gas turbine engine may be useful used in HRSB, thus will increase the capacity and efficiency of the steam turbine.

UR - http://www.scopus.com/inward/record.url?scp=85008657176&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85008657176&partnerID=8YFLogxK

U2 - 10.1051/matecconf/20179101004

DO - 10.1051/matecconf/20179101004

M3 - Article

AN - SCOPUS:85008657176

VL - 91

JO - MATEC Web of Conferences

JF - MATEC Web of Conferences

M1 - 01004

ER -