Probe Current Sources for Electrical Impedance Tomography

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Several circuit designs and hardware implementations of probe current sources for broadband electrical impedance measurements were compared. The basic parameters of the circuits were studied by numerical methods. Various hardware implementations were experimentally tested. Printed circuit board topologies providing parameters close to those obtained by model estimation were suggested.

Original languageEnglish
Pages (from-to)1-5
Number of pages5
JournalBiomedical Engineering
DOIs
Publication statusAccepted/In press - 30 Mar 2016

Fingerprint

Acoustic impedance
Electric Impedance
Tomography
Hardware
Networks (circuits)
Printed circuit boards
Numerical methods
Topology

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Biomedical Engineering
  • Medical Laboratory Technology

Cite this

@article{30a89be3e4f2429cab19dbe954427070,
title = "Probe Current Sources for Electrical Impedance Tomography",
abstract = "Several circuit designs and hardware implementations of probe current sources for broadband electrical impedance measurements were compared. The basic parameters of the circuits were studied by numerical methods. Various hardware implementations were experimentally tested. Printed circuit board topologies providing parameters close to those obtained by model estimation were suggested.",
author = "Brazovskii, {Konstantin Stanislavovich} and Pekker, {Yakov Semenovich} and Soldatov, {A. I.}",
year = "2016",
month = "3",
day = "30",
doi = "10.1007/s10527-016-9564-8",
language = "English",
pages = "1--5",
journal = "Bio-Medical Engineering",
issn = "0006-3398",
publisher = "Springer New York",

}

TY - JOUR

T1 - Probe Current Sources for Electrical Impedance Tomography

AU - Brazovskii, Konstantin Stanislavovich

AU - Pekker, Yakov Semenovich

AU - Soldatov, A. I.

PY - 2016/3/30

Y1 - 2016/3/30

N2 - Several circuit designs and hardware implementations of probe current sources for broadband electrical impedance measurements were compared. The basic parameters of the circuits were studied by numerical methods. Various hardware implementations were experimentally tested. Printed circuit board topologies providing parameters close to those obtained by model estimation were suggested.

AB - Several circuit designs and hardware implementations of probe current sources for broadband electrical impedance measurements were compared. The basic parameters of the circuits were studied by numerical methods. Various hardware implementations were experimentally tested. Printed circuit board topologies providing parameters close to those obtained by model estimation were suggested.

UR - http://www.scopus.com/inward/record.url?scp=84962233732&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962233732&partnerID=8YFLogxK

U2 - 10.1007/s10527-016-9564-8

DO - 10.1007/s10527-016-9564-8

M3 - Article

SP - 1

EP - 5

JO - Bio-Medical Engineering

JF - Bio-Medical Engineering

SN - 0006-3398

ER -