Prebreakdown phenomena in insulating gas mixtures under very fast transients

W. Pfeiffer, N. Kuzishin, M. Zhurkov

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 % / 90 %) gas mixture, SF 6/CO 2 (10 % / 90 %) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 %, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.

Original languageEnglish
Title of host publicationConference Record of IEEE International Symposium on Electrical Insulation
Pages488-491
Number of pages4
DOIs
Publication statusPublished - 2008
Event2008 IEEE International Symposium on Electrical Insulation, ISEI 2008 - Vancouver, BC, Canada
Duration: 9 Jun 200812 Jun 2008

Other

Other2008 IEEE International Symposium on Electrical Insulation, ISEI 2008
CountryCanada
CityVancouver, BC
Period9.6.0812.6.08

Fingerprint

Gas mixtures
Electric potential
Greenhouse effect
Gases
Insulation
Electric lines
Electric fields
Electrodes

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Building and Construction

Cite this

Pfeiffer, W., Kuzishin, N., & Zhurkov, M. (2008). Prebreakdown phenomena in insulating gas mixtures under very fast transients. In Conference Record of IEEE International Symposium on Electrical Insulation (pp. 488-491). [4570379] https://doi.org/10.1109/ELINSL.2008.4570379

Prebreakdown phenomena in insulating gas mixtures under very fast transients. / Pfeiffer, W.; Kuzishin, N.; Zhurkov, M.

Conference Record of IEEE International Symposium on Electrical Insulation. 2008. p. 488-491 4570379.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Pfeiffer, W, Kuzishin, N & Zhurkov, M 2008, Prebreakdown phenomena in insulating gas mixtures under very fast transients. in Conference Record of IEEE International Symposium on Electrical Insulation., 4570379, pp. 488-491, 2008 IEEE International Symposium on Electrical Insulation, ISEI 2008, Vancouver, BC, Canada, 9.6.08. https://doi.org/10.1109/ELINSL.2008.4570379
Pfeiffer W, Kuzishin N, Zhurkov M. Prebreakdown phenomena in insulating gas mixtures under very fast transients. In Conference Record of IEEE International Symposium on Electrical Insulation. 2008. p. 488-491. 4570379 https://doi.org/10.1109/ELINSL.2008.4570379
Pfeiffer, W. ; Kuzishin, N. ; Zhurkov, M. / Prebreakdown phenomena in insulating gas mixtures under very fast transients. Conference Record of IEEE International Symposium on Electrical Insulation. 2008. pp. 488-491
@inproceedings{90cd7cdbf8cf4ee1b428590145033912,
title = "Prebreakdown phenomena in insulating gas mixtures under very fast transients",
abstract = "For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 {\%} / 90 {\%}) gas mixture, SF 6/CO 2 (10 {\%} / 90 {\%}) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 {\%}, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.",
author = "W. Pfeiffer and N. Kuzishin and M. Zhurkov",
year = "2008",
doi = "10.1109/ELINSL.2008.4570379",
language = "English",
pages = "488--491",
booktitle = "Conference Record of IEEE International Symposium on Electrical Insulation",

}

TY - GEN

T1 - Prebreakdown phenomena in insulating gas mixtures under very fast transients

AU - Pfeiffer, W.

AU - Kuzishin, N.

AU - Zhurkov, M.

PY - 2008

Y1 - 2008

N2 - For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 % / 90 %) gas mixture, SF 6/CO 2 (10 % / 90 %) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 %, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.

AB - For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 % / 90 %) gas mixture, SF 6/CO 2 (10 % / 90 %) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 %, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.

UR - http://www.scopus.com/inward/record.url?scp=52049090553&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=52049090553&partnerID=8YFLogxK

U2 - 10.1109/ELINSL.2008.4570379

DO - 10.1109/ELINSL.2008.4570379

M3 - Conference contribution

AN - SCOPUS:52049090553

SP - 488

EP - 491

BT - Conference Record of IEEE International Symposium on Electrical Insulation

ER -