Polarographic and voltammetric determination of 6-nitrobenzimidazole and mechanism of its electrochemical reduction

Dana Deylová, Jiří Barek, Vlastimil Vyskočil

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Optimal conditions were found for the determination of 6-nitrobenzimidazole by tast polarography (at 1 × 10-4-1 × 10-6 mol 1-1), by differential pulse polarography at dropping mercury electrode (at 1 × 10-4-1 × 10-7 mol 1 -1), and by differential pulse voltammetry at hanging mercury drop electrode (at 1 × 10-4-1 × 10-8 mol 1 -1). Practical applicability of the developed methods was verified on the determination of 6-nitrobenzimidazole in drinking water (at 10-8 mol 1-1). Coulometry at constant potential and cyclic voltammetry were used for elucidation of the mechanism of electrochemical reduction.

Original languageEnglish
Pages (from-to)1443-1454
Number of pages12
JournalCollection of Czechoslovak Chemical Communications
Volume74
Issue number10
DOIs
Publication statusPublished - 1 Oct 2009
Externally publishedYes

Fingerprint

Polarographic analysis
Mercury
Coulometers
Electrodes
Voltammetry
Drinking Water
Cyclic voltammetry

Keywords

  • 6-nitrobenzimidazole
  • Constant potential coulometry
  • Cyclic voltammetry
  • Differential pulse polarography
  • Differential pulse voltammetry
  • Electrochemistry
  • Tast polarography

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Polarographic and voltammetric determination of 6-nitrobenzimidazole and mechanism of its electrochemical reduction. / Deylová, Dana; Barek, Jiří; Vyskočil, Vlastimil.

In: Collection of Czechoslovak Chemical Communications, Vol. 74, No. 10, 01.10.2009, p. 1443-1454.

Research output: Contribution to journalArticle

@article{ad8bcc14d876480f9a95eebd36dc212f,
title = "Polarographic and voltammetric determination of 6-nitrobenzimidazole and mechanism of its electrochemical reduction",
abstract = "Optimal conditions were found for the determination of 6-nitrobenzimidazole by tast polarography (at 1 × 10-4-1 × 10-6 mol 1-1), by differential pulse polarography at dropping mercury electrode (at 1 × 10-4-1 × 10-7 mol 1 -1), and by differential pulse voltammetry at hanging mercury drop electrode (at 1 × 10-4-1 × 10-8 mol 1 -1). Practical applicability of the developed methods was verified on the determination of 6-nitrobenzimidazole in drinking water (at 10-8 mol 1-1). Coulometry at constant potential and cyclic voltammetry were used for elucidation of the mechanism of electrochemical reduction.",
keywords = "6-nitrobenzimidazole, Constant potential coulometry, Cyclic voltammetry, Differential pulse polarography, Differential pulse voltammetry, Electrochemistry, Tast polarography",
author = "Dana Deylov{\'a} and Jiř{\'i} Barek and Vlastimil Vyskočil",
year = "2009",
month = "10",
day = "1",
doi = "10.1135/cccc2009059",
language = "English",
volume = "74",
pages = "1443--1454",
journal = "Collection of Czechoslovak Chemical Communications",
issn = "0010-0765",
publisher = "Czech Academy of Sciences",
number = "10",

}

TY - JOUR

T1 - Polarographic and voltammetric determination of 6-nitrobenzimidazole and mechanism of its electrochemical reduction

AU - Deylová, Dana

AU - Barek, Jiří

AU - Vyskočil, Vlastimil

PY - 2009/10/1

Y1 - 2009/10/1

N2 - Optimal conditions were found for the determination of 6-nitrobenzimidazole by tast polarography (at 1 × 10-4-1 × 10-6 mol 1-1), by differential pulse polarography at dropping mercury electrode (at 1 × 10-4-1 × 10-7 mol 1 -1), and by differential pulse voltammetry at hanging mercury drop electrode (at 1 × 10-4-1 × 10-8 mol 1 -1). Practical applicability of the developed methods was verified on the determination of 6-nitrobenzimidazole in drinking water (at 10-8 mol 1-1). Coulometry at constant potential and cyclic voltammetry were used for elucidation of the mechanism of electrochemical reduction.

AB - Optimal conditions were found for the determination of 6-nitrobenzimidazole by tast polarography (at 1 × 10-4-1 × 10-6 mol 1-1), by differential pulse polarography at dropping mercury electrode (at 1 × 10-4-1 × 10-7 mol 1 -1), and by differential pulse voltammetry at hanging mercury drop electrode (at 1 × 10-4-1 × 10-8 mol 1 -1). Practical applicability of the developed methods was verified on the determination of 6-nitrobenzimidazole in drinking water (at 10-8 mol 1-1). Coulometry at constant potential and cyclic voltammetry were used for elucidation of the mechanism of electrochemical reduction.

KW - 6-nitrobenzimidazole

KW - Constant potential coulometry

KW - Cyclic voltammetry

KW - Differential pulse polarography

KW - Differential pulse voltammetry

KW - Electrochemistry

KW - Tast polarography

UR - http://www.scopus.com/inward/record.url?scp=77149139114&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77149139114&partnerID=8YFLogxK

U2 - 10.1135/cccc2009059

DO - 10.1135/cccc2009059

M3 - Article

AN - SCOPUS:77149139114

VL - 74

SP - 1443

EP - 1454

JO - Collection of Czechoslovak Chemical Communications

JF - Collection of Czechoslovak Chemical Communications

SN - 0010-0765

IS - 10

ER -