Polarographic and voltammetric determination of 1-nitropyrene

Jiří Barek, Jiří Zima, Josino C. Moreira, Alexandr Muck

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

The polarographic behaviour of 1-nitropyrene was investigated by last polarography, differential pulse polarography (both with a dropping mercury electrode), differential pulse voltammetry, and adsorptive stripping voltammetry (both with a hanging mercury drop electrode). Optimum conditions have been found for its determination by the given methods in the concentration ranges 2-100, 0.2-100, 0.1-10, and 0.001-0.01 μmol l-1, respectively.

Original languageEnglish
Pages (from-to)1888-1896
Number of pages9
JournalCollection of Czechoslovak Chemical Communications
Volume65
Issue number12
DOIs
Publication statusPublished - 1 Jan 2000
Externally publishedYes

Fingerprint

1-nitropyrene
Polarographic analysis
Voltammetry
Mercury
Electrodes

Keywords

  • 1-Nitropyrene
  • Carcinogens, Electrochemistry
  • Polarography
  • Voltammetry

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Polarographic and voltammetric determination of 1-nitropyrene. / Barek, Jiří; Zima, Jiří; Moreira, Josino C.; Muck, Alexandr.

In: Collection of Czechoslovak Chemical Communications, Vol. 65, No. 12, 01.01.2000, p. 1888-1896.

Research output: Contribution to journalArticle

Barek, Jiří ; Zima, Jiří ; Moreira, Josino C. ; Muck, Alexandr. / Polarographic and voltammetric determination of 1-nitropyrene. In: Collection of Czechoslovak Chemical Communications. 2000 ; Vol. 65, No. 12. pp. 1888-1896.
@article{5af92bdaf96449d1bf0bff52f8caa683,
title = "Polarographic and voltammetric determination of 1-nitropyrene",
abstract = "The polarographic behaviour of 1-nitropyrene was investigated by last polarography, differential pulse polarography (both with a dropping mercury electrode), differential pulse voltammetry, and adsorptive stripping voltammetry (both with a hanging mercury drop electrode). Optimum conditions have been found for its determination by the given methods in the concentration ranges 2-100, 0.2-100, 0.1-10, and 0.001-0.01 μmol l-1, respectively.",
keywords = "1-Nitropyrene, Carcinogens, Electrochemistry, Polarography, Voltammetry",
author = "Jiř{\'i} Barek and Jiř{\'i} Zima and Moreira, {Josino C.} and Alexandr Muck",
year = "2000",
month = "1",
day = "1",
doi = "10.1135/cccc20001888",
language = "English",
volume = "65",
pages = "1888--1896",
journal = "Collection of Czechoslovak Chemical Communications",
issn = "0010-0765",
publisher = "Czech Academy of Sciences",
number = "12",

}

TY - JOUR

T1 - Polarographic and voltammetric determination of 1-nitropyrene

AU - Barek, Jiří

AU - Zima, Jiří

AU - Moreira, Josino C.

AU - Muck, Alexandr

PY - 2000/1/1

Y1 - 2000/1/1

N2 - The polarographic behaviour of 1-nitropyrene was investigated by last polarography, differential pulse polarography (both with a dropping mercury electrode), differential pulse voltammetry, and adsorptive stripping voltammetry (both with a hanging mercury drop electrode). Optimum conditions have been found for its determination by the given methods in the concentration ranges 2-100, 0.2-100, 0.1-10, and 0.001-0.01 μmol l-1, respectively.

AB - The polarographic behaviour of 1-nitropyrene was investigated by last polarography, differential pulse polarography (both with a dropping mercury electrode), differential pulse voltammetry, and adsorptive stripping voltammetry (both with a hanging mercury drop electrode). Optimum conditions have been found for its determination by the given methods in the concentration ranges 2-100, 0.2-100, 0.1-10, and 0.001-0.01 μmol l-1, respectively.

KW - 1-Nitropyrene

KW - Carcinogens, Electrochemistry

KW - Polarography

KW - Voltammetry

UR - http://www.scopus.com/inward/record.url?scp=23044525866&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=23044525866&partnerID=8YFLogxK

U2 - 10.1135/cccc20001888

DO - 10.1135/cccc20001888

M3 - Article

AN - SCOPUS:23044525866

VL - 65

SP - 1888

EP - 1896

JO - Collection of Czechoslovak Chemical Communications

JF - Collection of Czechoslovak Chemical Communications

SN - 0010-0765

IS - 12

ER -