Plastic deformation and fracture caused by coating-substrate mismatch at mesoscale

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

A large amount of experimental data obtained from the television-optical measurement technique (TOMSC) have been analyzed to identify the main mechanisms of plastic deformation at the mesoscale level for coated and surface-hardened materials. Among the factors to be concerned are the site of nucleation and relaxation of mesostress concentrators, the geometry and interface structure of which can influence the outcome.

Original languageEnglish
Pages (from-to)1-8
Number of pages8
JournalTheoretical and Applied Fracture Mechanics
Volume35
Issue number1
DOIs
Publication statusPublished - Jan 2001

ASJC Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials

Fingerprint Dive into the research topics of 'Plastic deformation and fracture caused by coating-substrate mismatch at mesoscale'. Together they form a unique fingerprint.