Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal

Yu N. Adishchev, V. N. Zabaev, V. V. Kaplin, S. V. Kazin, S. R. Uglov, S. I. Kuznetsov, Yu P. Kunashenko

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Parametric x-ray radiation (PXR) from a mosaic pyrolytic graphite crystal is studied using a 5.7 MeV electron beam. The first-order [002[ PXR reflection is detected in the Bragg angle, with the emitted photon energies peaking around 8 MeV. The detection angle ΘD=2Θ B=27°with respect to the e-beam, where ΘB is the Bragg angle. The target is 0.3 mm thick, and the PXR spectra are measured for different tilt angles between the target and the e-beam direction.

Original languageEnglish
Title of host publicationProceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages300-302
Number of pages3
ISBN (Print)0780374274, 9780780374270
DOIs
Publication statusPublished - 2002
Event6th Russian-Korean International Symposium on Science and Technology, KORUS 2002 - Novosibirsk, Russian Federation
Duration: 24 Jun 200230 Jun 2002

Other

Other6th Russian-Korean International Symposium on Science and Technology, KORUS 2002
CountryRussian Federation
CityNovosibirsk
Period24.6.0230.6.02

Fingerprint

Graphite
X-Rays
Electrons
Radiation
X rays
Crystals
Photons
Electron beams

Keywords

  • Parametric x-ray radiation
  • relativistic electrons

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Electrical and Electronic Engineering
  • Industrial and Manufacturing Engineering
  • Mechanics of Materials
  • Architecture
  • Electronic, Optical and Magnetic Materials
  • Medicine (miscellaneous)

Cite this

Adishchev, Y. N., Zabaev, V. N., Kaplin, V. V., Kazin, S. V., Uglov, S. R., Kuznetsov, S. I., & Kunashenko, Y. P. (2002). Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal. In Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002 (pp. 300-302). [1028024] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/KORUS.2002.1028024

Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal. / Adishchev, Yu N.; Zabaev, V. N.; Kaplin, V. V.; Kazin, S. V.; Uglov, S. R.; Kuznetsov, S. I.; Kunashenko, Yu P.

Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002. Institute of Electrical and Electronics Engineers Inc., 2002. p. 300-302 1028024.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Adishchev, YN, Zabaev, VN, Kaplin, VV, Kazin, SV, Uglov, SR, Kuznetsov, SI & Kunashenko, YP 2002, Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal. in Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002., 1028024, Institute of Electrical and Electronics Engineers Inc., pp. 300-302, 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002, Novosibirsk, Russian Federation, 24.6.02. https://doi.org/10.1109/KORUS.2002.1028024
Adishchev YN, Zabaev VN, Kaplin VV, Kazin SV, Uglov SR, Kuznetsov SI et al. Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal. In Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002. Institute of Electrical and Electronics Engineers Inc. 2002. p. 300-302. 1028024 https://doi.org/10.1109/KORUS.2002.1028024
Adishchev, Yu N. ; Zabaev, V. N. ; Kaplin, V. V. ; Kazin, S. V. ; Uglov, S. R. ; Kuznetsov, S. I. ; Kunashenko, Yu P. / Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal. Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002. Institute of Electrical and Electronics Engineers Inc., 2002. pp. 300-302
@inproceedings{4f9967926e744ab7abc59d532c30144a,
title = "Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal",
abstract = "Parametric x-ray radiation (PXR) from a mosaic pyrolytic graphite crystal is studied using a 5.7 MeV electron beam. The first-order [002[ PXR reflection is detected in the Bragg angle, with the emitted photon energies peaking around 8 MeV. The detection angle ΘD=2Θ B=27°with respect to the e-beam, where ΘB is the Bragg angle. The target is 0.3 mm thick, and the PXR spectra are measured for different tilt angles between the target and the e-beam direction.",
keywords = "Parametric x-ray radiation, relativistic electrons",
author = "Adishchev, {Yu N.} and Zabaev, {V. N.} and Kaplin, {V. V.} and Kazin, {S. V.} and Uglov, {S. R.} and Kuznetsov, {S. I.} and Kunashenko, {Yu P.}",
year = "2002",
doi = "10.1109/KORUS.2002.1028024",
language = "English",
isbn = "0780374274",
pages = "300--302",
booktitle = "Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Parametric x-ray radiation of 5.7 MeV electrons from a pyrolytic graphite crystal

AU - Adishchev, Yu N.

AU - Zabaev, V. N.

AU - Kaplin, V. V.

AU - Kazin, S. V.

AU - Uglov, S. R.

AU - Kuznetsov, S. I.

AU - Kunashenko, Yu P.

PY - 2002

Y1 - 2002

N2 - Parametric x-ray radiation (PXR) from a mosaic pyrolytic graphite crystal is studied using a 5.7 MeV electron beam. The first-order [002[ PXR reflection is detected in the Bragg angle, with the emitted photon energies peaking around 8 MeV. The detection angle ΘD=2Θ B=27°with respect to the e-beam, where ΘB is the Bragg angle. The target is 0.3 mm thick, and the PXR spectra are measured for different tilt angles between the target and the e-beam direction.

AB - Parametric x-ray radiation (PXR) from a mosaic pyrolytic graphite crystal is studied using a 5.7 MeV electron beam. The first-order [002[ PXR reflection is detected in the Bragg angle, with the emitted photon energies peaking around 8 MeV. The detection angle ΘD=2Θ B=27°with respect to the e-beam, where ΘB is the Bragg angle. The target is 0.3 mm thick, and the PXR spectra are measured for different tilt angles between the target and the e-beam direction.

KW - Parametric x-ray radiation

KW - relativistic electrons

UR - http://www.scopus.com/inward/record.url?scp=84961661700&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84961661700&partnerID=8YFLogxK

U2 - 10.1109/KORUS.2002.1028024

DO - 10.1109/KORUS.2002.1028024

M3 - Conference contribution

AN - SCOPUS:84961661700

SN - 0780374274

SN - 9780780374270

SP - 300

EP - 302

BT - Proceedings - 6th Russian-Korean International Symposium on Science and Technology, KORUS 2002

PB - Institute of Electrical and Electronics Engineers Inc.

ER -