Parallel work of pseudospark dischargers for general load

K. A. Klimenko, A. V. Kolesnikov, Yu D. Korolev, V. G. Rabotkin, I. A. Shemyazkin

    Research output: Contribution to journalArticle

    Abstract

    The research results have been presented for time-delays of the coming into action of pseudospark dischargers depending on anode voltage, gas pressure and start-up voltage. Operational conditions were selected to switch parallel a bank of capacitors for the general load in low-inductive electric networks. The mode of the parallel work of six dischargers has been implemented with 10 kamp current switched and with the pulse durability by the base ≈300 ns. It is pointed that special capacitors with minimum inductance of their own were used in experiments and the inductive decoupling between dischargers was minimal.

    Original languageEnglish
    Pages (from-to)135-139
    Number of pages5
    JournalPribory i Tekhnika Eksperimenta
    Issue number6
    Publication statusPublished - Nov 1992

    Fingerprint

    dischargers
    Capacitors
    Circuit theory
    capacitors
    Electric potential
    electric networks
    Inductance
    Time delay
    Anodes
    Durability
    Switches
    electric potential
    durability
    inductance
    decoupling
    gas pressure
    anodes
    time lag
    Gases
    Experiments

    ASJC Scopus subject areas

    • Instrumentation

    Cite this

    Klimenko, K. A., Kolesnikov, A. V., Korolev, Y. D., Rabotkin, V. G., & Shemyazkin, I. A. (1992). Parallel work of pseudospark dischargers for general load. Pribory i Tekhnika Eksperimenta, (6), 135-139.

    Parallel work of pseudospark dischargers for general load. / Klimenko, K. A.; Kolesnikov, A. V.; Korolev, Yu D.; Rabotkin, V. G.; Shemyazkin, I. A.

    In: Pribory i Tekhnika Eksperimenta, No. 6, 11.1992, p. 135-139.

    Research output: Contribution to journalArticle

    Klimenko, KA, Kolesnikov, AV, Korolev, YD, Rabotkin, VG & Shemyazkin, IA 1992, 'Parallel work of pseudospark dischargers for general load', Pribory i Tekhnika Eksperimenta, no. 6, pp. 135-139.
    Klimenko KA, Kolesnikov AV, Korolev YD, Rabotkin VG, Shemyazkin IA. Parallel work of pseudospark dischargers for general load. Pribory i Tekhnika Eksperimenta. 1992 Nov;(6):135-139.
    Klimenko, K. A. ; Kolesnikov, A. V. ; Korolev, Yu D. ; Rabotkin, V. G. ; Shemyazkin, I. A. / Parallel work of pseudospark dischargers for general load. In: Pribory i Tekhnika Eksperimenta. 1992 ; No. 6. pp. 135-139.
    @article{32bcf30b3d1f4a42a09c5d3b1e50fb40,
    title = "Parallel work of pseudospark dischargers for general load",
    abstract = "The research results have been presented for time-delays of the coming into action of pseudospark dischargers depending on anode voltage, gas pressure and start-up voltage. Operational conditions were selected to switch parallel a bank of capacitors for the general load in low-inductive electric networks. The mode of the parallel work of six dischargers has been implemented with 10 kamp current switched and with the pulse durability by the base ≈300 ns. It is pointed that special capacitors with minimum inductance of their own were used in experiments and the inductive decoupling between dischargers was minimal.",
    author = "Klimenko, {K. A.} and Kolesnikov, {A. V.} and Korolev, {Yu D.} and Rabotkin, {V. G.} and Shemyazkin, {I. A.}",
    year = "1992",
    month = "11",
    language = "English",
    pages = "135--139",
    journal = "Pribory i Tekhnika Eksperimenta",
    issn = "0032-8162",
    publisher = "Izdatel'stvo Nauka",
    number = "6",

    }

    TY - JOUR

    T1 - Parallel work of pseudospark dischargers for general load

    AU - Klimenko, K. A.

    AU - Kolesnikov, A. V.

    AU - Korolev, Yu D.

    AU - Rabotkin, V. G.

    AU - Shemyazkin, I. A.

    PY - 1992/11

    Y1 - 1992/11

    N2 - The research results have been presented for time-delays of the coming into action of pseudospark dischargers depending on anode voltage, gas pressure and start-up voltage. Operational conditions were selected to switch parallel a bank of capacitors for the general load in low-inductive electric networks. The mode of the parallel work of six dischargers has been implemented with 10 kamp current switched and with the pulse durability by the base ≈300 ns. It is pointed that special capacitors with minimum inductance of their own were used in experiments and the inductive decoupling between dischargers was minimal.

    AB - The research results have been presented for time-delays of the coming into action of pseudospark dischargers depending on anode voltage, gas pressure and start-up voltage. Operational conditions were selected to switch parallel a bank of capacitors for the general load in low-inductive electric networks. The mode of the parallel work of six dischargers has been implemented with 10 kamp current switched and with the pulse durability by the base ≈300 ns. It is pointed that special capacitors with minimum inductance of their own were used in experiments and the inductive decoupling between dischargers was minimal.

    UR - http://www.scopus.com/inward/record.url?scp=0026944946&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0026944946&partnerID=8YFLogxK

    M3 - Article

    AN - SCOPUS:0026944946

    SP - 135

    EP - 139

    JO - Pribory i Tekhnika Eksperimenta

    JF - Pribory i Tekhnika Eksperimenta

    SN - 0032-8162

    IS - 6

    ER -