Operation reliability analysis of independent power plants of gas-transmission system distant production facilities

Maksim Vladimirovich Piskunov, Ivan S. Voytkov, Olga V. Vysokomornaya, Vladimir S. Vysokomorny

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

The new approach was developed to analyze the failure causes in operation of linear facilities independent power supply sources (mini-CHP-plants) of gas-transmission system in Eastern part of Russia. Triggering conditions of ceiling operation substance temperature at condenser output were determined with mathematical simulation use of unsteady heat and mass transfer processes in condenser of mini-CHP-plants. Under these conditions the failure probability in operation of independent power supply sources is increased. Influence of environmental factors (in particular, ambient temperature) as well as output electric capability values of power plant on mini-CHP-plant operation reliability was analyzed. Values of mean time to failure and power plant failure density during operation in different regions of Eastern Siberia and Far East of Russia were received with use of numerical simulation results of heat and mass transfer processes at operation substance condensation.

Original languageEnglish
Title of host publicationEPJ Web of Conferences
PublisherEDP Sciences
Volume82
DOIs
Publication statusPublished - 20 Jan 2015
EventThermophysical Basis of Energy Technologies - 2014 - Tomsk, Russian Federation
Duration: 15 Oct 201417 Oct 2014

Other

OtherThermophysical Basis of Energy Technologies - 2014
CountryRussian Federation
CityTomsk
Period15.10.1417.10.14

Fingerprint

reliability analysis
power plants
gases
condensers
Russian Federation
power supplies
mass transfer
heat transfer
Siberia
ceilings
output
ambient temperature
simulation
condensation
causes

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Operation reliability analysis of independent power plants of gas-transmission system distant production facilities. / Piskunov, Maksim Vladimirovich; Voytkov, Ivan S.; Vysokomornaya, Olga V.; Vysokomorny, Vladimir S.

EPJ Web of Conferences. Vol. 82 EDP Sciences, 2015. 01011.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Piskunov, MV, Voytkov, IS, Vysokomornaya, OV & Vysokomorny, VS 2015, Operation reliability analysis of independent power plants of gas-transmission system distant production facilities. in EPJ Web of Conferences. vol. 82, 01011, EDP Sciences, Thermophysical Basis of Energy Technologies - 2014, Tomsk, Russian Federation, 15.10.14. https://doi.org/10.1051/epjconf/20158201011
@inproceedings{9d162d6c812b4dca96f323241567c42e,
title = "Operation reliability analysis of independent power plants of gas-transmission system distant production facilities",
abstract = "The new approach was developed to analyze the failure causes in operation of linear facilities independent power supply sources (mini-CHP-plants) of gas-transmission system in Eastern part of Russia. Triggering conditions of ceiling operation substance temperature at condenser output were determined with mathematical simulation use of unsteady heat and mass transfer processes in condenser of mini-CHP-plants. Under these conditions the failure probability in operation of independent power supply sources is increased. Influence of environmental factors (in particular, ambient temperature) as well as output electric capability values of power plant on mini-CHP-plant operation reliability was analyzed. Values of mean time to failure and power plant failure density during operation in different regions of Eastern Siberia and Far East of Russia were received with use of numerical simulation results of heat and mass transfer processes at operation substance condensation.",
author = "Maksim Vladimirovich Piskunov and Voytkov, {Ivan S.} and Vysokomornaya, {Olga V.} and Vysokomorny, {Vladimir S.}",
year = "2015",
month = "1",
day = "20",
doi = "10.1051/epjconf/20158201011",
language = "English",
volume = "82",
booktitle = "EPJ Web of Conferences",
publisher = "EDP Sciences",

}

TY - GEN

T1 - Operation reliability analysis of independent power plants of gas-transmission system distant production facilities

AU - Piskunov, Maksim Vladimirovich

AU - Voytkov, Ivan S.

AU - Vysokomornaya, Olga V.

AU - Vysokomorny, Vladimir S.

PY - 2015/1/20

Y1 - 2015/1/20

N2 - The new approach was developed to analyze the failure causes in operation of linear facilities independent power supply sources (mini-CHP-plants) of gas-transmission system in Eastern part of Russia. Triggering conditions of ceiling operation substance temperature at condenser output were determined with mathematical simulation use of unsteady heat and mass transfer processes in condenser of mini-CHP-plants. Under these conditions the failure probability in operation of independent power supply sources is increased. Influence of environmental factors (in particular, ambient temperature) as well as output electric capability values of power plant on mini-CHP-plant operation reliability was analyzed. Values of mean time to failure and power plant failure density during operation in different regions of Eastern Siberia and Far East of Russia were received with use of numerical simulation results of heat and mass transfer processes at operation substance condensation.

AB - The new approach was developed to analyze the failure causes in operation of linear facilities independent power supply sources (mini-CHP-plants) of gas-transmission system in Eastern part of Russia. Triggering conditions of ceiling operation substance temperature at condenser output were determined with mathematical simulation use of unsteady heat and mass transfer processes in condenser of mini-CHP-plants. Under these conditions the failure probability in operation of independent power supply sources is increased. Influence of environmental factors (in particular, ambient temperature) as well as output electric capability values of power plant on mini-CHP-plant operation reliability was analyzed. Values of mean time to failure and power plant failure density during operation in different regions of Eastern Siberia and Far East of Russia were received with use of numerical simulation results of heat and mass transfer processes at operation substance condensation.

UR - http://www.scopus.com/inward/record.url?scp=84921736624&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84921736624&partnerID=8YFLogxK

U2 - 10.1051/epjconf/20158201011

DO - 10.1051/epjconf/20158201011

M3 - Conference contribution

VL - 82

BT - EPJ Web of Conferences

PB - EDP Sciences

ER -