Abstract
The development of CT-simulation leads to major improvements in radiation therapy treatment planning. However it is not clear whether this new technology has evolved to the point of completely eliminating the "physical simulator". At present there is an ongoing debate about the significance of virtual simulation in the treatment planning process and its limitations for different clinical purposes. The purpose of this study is to measure the accuracy in the determination of the isocenter in a virtual simulation process and to report about parameters which influence on the precision of its determination.
Original language | English |
---|---|
Title of host publication | AIP Conference Proceedings |
Pages | 254-255 |
Number of pages | 2 |
Volume | 958 |
DOIs | |
Publication status | Published - 2007 |
Event | 4th International Summer School on Nuclear Physics Methods and Accelerators in Biology and Medicine - Prague, Czech Republic Duration: 8 Jul 2007 → 19 Jul 2007 |
Other
Other | 4th International Summer School on Nuclear Physics Methods and Accelerators in Biology and Medicine |
---|---|
Country | Czech Republic |
City | Prague |
Period | 8.7.07 → 19.7.07 |
Fingerprint
Keywords
- Computed tomography
- Simulation
ASJC Scopus subject areas
- Physics and Astronomy(all)
Cite this
On the commissioning of CT-simulation in radiotherapy treatment planning : A phantom study. / Fotina, I.; Bogner, J.; Georg, D.; Poljanc, K.
AIP Conference Proceedings. Vol. 958 2007. p. 254-255.Research output: Chapter in Book/Report/Conference proceeding › Conference contribution
}
TY - GEN
T1 - On the commissioning of CT-simulation in radiotherapy treatment planning
T2 - A phantom study
AU - Fotina, I.
AU - Bogner, J.
AU - Georg, D.
AU - Poljanc, K.
PY - 2007
Y1 - 2007
N2 - The development of CT-simulation leads to major improvements in radiation therapy treatment planning. However it is not clear whether this new technology has evolved to the point of completely eliminating the "physical simulator". At present there is an ongoing debate about the significance of virtual simulation in the treatment planning process and its limitations for different clinical purposes. The purpose of this study is to measure the accuracy in the determination of the isocenter in a virtual simulation process and to report about parameters which influence on the precision of its determination.
AB - The development of CT-simulation leads to major improvements in radiation therapy treatment planning. However it is not clear whether this new technology has evolved to the point of completely eliminating the "physical simulator". At present there is an ongoing debate about the significance of virtual simulation in the treatment planning process and its limitations for different clinical purposes. The purpose of this study is to measure the accuracy in the determination of the isocenter in a virtual simulation process and to report about parameters which influence on the precision of its determination.
KW - Computed tomography
KW - Simulation
UR - http://www.scopus.com/inward/record.url?scp=71749090999&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=71749090999&partnerID=8YFLogxK
U2 - 10.1063/1.2825804
DO - 10.1063/1.2825804
M3 - Conference contribution
AN - SCOPUS:71749090999
SN - 9780735404724