Numerical analysis of the heat loss of stop valves of heat networks

Vyacheslav Polovnikov, Anatolij Vergun, Vasilij Sergeenko

Research output: Contribution to journalArticle

Abstract

The results of mathematical modeling of heat regimes of stop valves of heat networks were given. It was revealed that for the stop valves with a relatively small nominal bore the equivalent pipe length can be reduced more than twice.

Original languageEnglish
Article number01067
JournalMATEC Web of Conferences
Volume110
DOIs
Publication statusPublished - 19 Jun 2017

Fingerprint

Heat losses
Numerical analysis
Pipe
Hot Temperature

ASJC Scopus subject areas

  • Chemistry(all)
  • Engineering(all)
  • Materials Science(all)

Cite this

Numerical analysis of the heat loss of stop valves of heat networks. / Polovnikov, Vyacheslav; Vergun, Anatolij; Sergeenko, Vasilij.

In: MATEC Web of Conferences, Vol. 110, 01067, 19.06.2017.

Research output: Contribution to journalArticle

@article{15d48e826115409a9868f7d0f6425993,
title = "Numerical analysis of the heat loss of stop valves of heat networks",
abstract = "The results of mathematical modeling of heat regimes of stop valves of heat networks were given. It was revealed that for the stop valves with a relatively small nominal bore the equivalent pipe length can be reduced more than twice.",
author = "Vyacheslav Polovnikov and Anatolij Vergun and Vasilij Sergeenko",
year = "2017",
month = "6",
day = "19",
doi = "10.1051/matecconf/201711001067",
language = "English",
volume = "110",
journal = "MATEC Web of Conferences",

}

TY - JOUR

T1 - Numerical analysis of the heat loss of stop valves of heat networks

AU - Polovnikov, Vyacheslav

AU - Vergun, Anatolij

AU - Sergeenko, Vasilij

PY - 2017/6/19

Y1 - 2017/6/19

N2 - The results of mathematical modeling of heat regimes of stop valves of heat networks were given. It was revealed that for the stop valves with a relatively small nominal bore the equivalent pipe length can be reduced more than twice.

AB - The results of mathematical modeling of heat regimes of stop valves of heat networks were given. It was revealed that for the stop valves with a relatively small nominal bore the equivalent pipe length can be reduced more than twice.

UR - http://www.scopus.com/inward/record.url?scp=85021351867&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021351867&partnerID=8YFLogxK

U2 - 10.1051/matecconf/201711001067

DO - 10.1051/matecconf/201711001067

M3 - Article

VL - 110

JO - MATEC Web of Conferences

JF - MATEC Web of Conferences

M1 - 01067

ER -