Nomograms for calculation of defense shield from X-ray

V. I. Bespalov, M. M. Shtejn, E. N. Kotenko

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The paper presents new nomograms to calculate the thickness of the shield against direct x-ray radiation in the 75-450 kV voltage range. Nomograms were obtained for the main shield materials: lead, iron, concrete, and were based on the spectral composition of source's radiation, on the contribution of secondary radiation. It is assumed that new standards of radiation safety NRB-96, will be taken into account. It is pointed out that all operating objects and productions should observe NRB-96 standards, in 2000. It is underscored that suitable, simple and reliable methods of calculating shield are necessary to accelerate this work.

Original languageEnglish
Pages (from-to)44-55
Number of pages12
JournalDefektoskopiya
Issue number7
Publication statusPublished - 2000

Fingerprint

Nomograms
Radiation
X rays
Lead
Concretes
Iron
Electric potential
Chemical analysis

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Bespalov, V. I., Shtejn, M. M., & Kotenko, E. N. (2000). Nomograms for calculation of defense shield from X-ray. Defektoskopiya, (7), 44-55.

Nomograms for calculation of defense shield from X-ray. / Bespalov, V. I.; Shtejn, M. M.; Kotenko, E. N.

In: Defektoskopiya, No. 7, 2000, p. 44-55.

Research output: Contribution to journalArticle

Bespalov, VI, Shtejn, MM & Kotenko, EN 2000, 'Nomograms for calculation of defense shield from X-ray', Defektoskopiya, no. 7, pp. 44-55.
Bespalov, V. I. ; Shtejn, M. M. ; Kotenko, E. N. / Nomograms for calculation of defense shield from X-ray. In: Defektoskopiya. 2000 ; No. 7. pp. 44-55.
@article{fa6c053789584417a94ad9aac6191f5f,
title = "Nomograms for calculation of defense shield from X-ray",
abstract = "The paper presents new nomograms to calculate the thickness of the shield against direct x-ray radiation in the 75-450 kV voltage range. Nomograms were obtained for the main shield materials: lead, iron, concrete, and were based on the spectral composition of source's radiation, on the contribution of secondary radiation. It is assumed that new standards of radiation safety NRB-96, will be taken into account. It is pointed out that all operating objects and productions should observe NRB-96 standards, in 2000. It is underscored that suitable, simple and reliable methods of calculating shield are necessary to accelerate this work.",
author = "Bespalov, {V. I.} and Shtejn, {M. M.} and Kotenko, {E. N.}",
year = "2000",
language = "English",
pages = "44--55",
journal = "Defektoskopiya",
issn = "0130-3082",
publisher = "Izdatel'stvo Nauka",
number = "7",

}

TY - JOUR

T1 - Nomograms for calculation of defense shield from X-ray

AU - Bespalov, V. I.

AU - Shtejn, M. M.

AU - Kotenko, E. N.

PY - 2000

Y1 - 2000

N2 - The paper presents new nomograms to calculate the thickness of the shield against direct x-ray radiation in the 75-450 kV voltage range. Nomograms were obtained for the main shield materials: lead, iron, concrete, and were based on the spectral composition of source's radiation, on the contribution of secondary radiation. It is assumed that new standards of radiation safety NRB-96, will be taken into account. It is pointed out that all operating objects and productions should observe NRB-96 standards, in 2000. It is underscored that suitable, simple and reliable methods of calculating shield are necessary to accelerate this work.

AB - The paper presents new nomograms to calculate the thickness of the shield against direct x-ray radiation in the 75-450 kV voltage range. Nomograms were obtained for the main shield materials: lead, iron, concrete, and were based on the spectral composition of source's radiation, on the contribution of secondary radiation. It is assumed that new standards of radiation safety NRB-96, will be taken into account. It is pointed out that all operating objects and productions should observe NRB-96 standards, in 2000. It is underscored that suitable, simple and reliable methods of calculating shield are necessary to accelerate this work.

UR - http://www.scopus.com/inward/record.url?scp=2542452995&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2542452995&partnerID=8YFLogxK

M3 - Article

SP - 44

EP - 55

JO - Defektoskopiya

JF - Defektoskopiya

SN - 0130-3082

IS - 7

ER -