Abstract
Negative- and zero-sequence-current filters based on inductance coil and magnetically operated switch with control winding without the use of current transformers are considered. The technique is presented for the calculation of coordinates of the points where the inductance coil and magnetically operated switch should be mounted for the cases of triangle and parallel arrangements of conductors of three phases of an electrical installation. The main unit for mounting the inductance coil and magnetically operated switch with the control winding near the electrical installation phases conductors is described. The relations for the parameters of filter components are derived. An example of the calculation of these parameters is given.
Original language | English |
---|---|
Pages (from-to) | 85-91 |
Number of pages | 7 |
Journal | International Journal of Electrical Power and Energy Systems |
Volume | 101 |
DOIs | |
Publication status | Published - 1 Oct 2018 |
Fingerprint
Keywords
- Current filter
- Electrical installation
- Electrical pathway
- Induction
- Magnetic field
- Magnetically operated sealed switch
- Winding
ASJC Scopus subject areas
- Energy Engineering and Power Technology
- Electrical and Electronic Engineering
Cite this
New filters for symetrical current components. / Kletsel, Mark; Zhantlesova, Asemgul; Mayshev, Pavel; Mashrapov, Bauyrzhan; Issabekov, Dauren.
In: International Journal of Electrical Power and Energy Systems, Vol. 101, 01.10.2018, p. 85-91.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - New filters for symetrical current components
AU - Kletsel, Mark
AU - Zhantlesova, Asemgul
AU - Mayshev, Pavel
AU - Mashrapov, Bauyrzhan
AU - Issabekov, Dauren
PY - 2018/10/1
Y1 - 2018/10/1
N2 - Negative- and zero-sequence-current filters based on inductance coil and magnetically operated switch with control winding without the use of current transformers are considered. The technique is presented for the calculation of coordinates of the points where the inductance coil and magnetically operated switch should be mounted for the cases of triangle and parallel arrangements of conductors of three phases of an electrical installation. The main unit for mounting the inductance coil and magnetically operated switch with the control winding near the electrical installation phases conductors is described. The relations for the parameters of filter components are derived. An example of the calculation of these parameters is given.
AB - Negative- and zero-sequence-current filters based on inductance coil and magnetically operated switch with control winding without the use of current transformers are considered. The technique is presented for the calculation of coordinates of the points where the inductance coil and magnetically operated switch should be mounted for the cases of triangle and parallel arrangements of conductors of three phases of an electrical installation. The main unit for mounting the inductance coil and magnetically operated switch with the control winding near the electrical installation phases conductors is described. The relations for the parameters of filter components are derived. An example of the calculation of these parameters is given.
KW - Current filter
KW - Electrical installation
KW - Electrical pathway
KW - Induction
KW - Magnetic field
KW - Magnetically operated sealed switch
KW - Winding
UR - http://www.scopus.com/inward/record.url?scp=85044141788&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85044141788&partnerID=8YFLogxK
U2 - 10.1016/j.ijepes.2018.03.005
DO - 10.1016/j.ijepes.2018.03.005
M3 - Article
AN - SCOPUS:85044141788
VL - 101
SP - 85
EP - 91
JO - International Journal of Electrical Power and Energy Systems
JF - International Journal of Electrical Power and Energy Systems
SN - 0142-0615
ER -