Multiplicative method for reduction of bias in indirect digital measurement result

Sergey V. Muravyov, Galina V. Zlygosteva, Valeriy N. Borikov

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The error reduction technique, based on inverse transformation, for a shunt active resistance measurement using an ammeter and voltmeter is considered. When computing a corrected reading only multiplicative operations on two measurement results are used, namely squaring and division. The proposed method allows to increase re-sistance measurement accuracy by about two orders of magnitude what has been validated by both theoretical and experimental outcomes.

Original languageEnglish
Pages (from-to)481-490
Number of pages10
JournalMetrology and Measurement Systems
Volume18
Issue number3
DOIs
Publication statusPublished - 6 Sep 2011

Fingerprint

ammeters
Ammeters
Voltmeters
voltmeters
shunts
division

Keywords

  • Bias
  • Error reduction technique
  • Indirect measurement
  • Shunt ohmic resistance

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Instrumentation

Cite this

Multiplicative method for reduction of bias in indirect digital measurement result. / Muravyov, Sergey V.; Zlygosteva, Galina V.; Borikov, Valeriy N.

In: Metrology and Measurement Systems, Vol. 18, No. 3, 06.09.2011, p. 481-490.

Research output: Contribution to journalArticle

@article{23c743fc0d314c9ea8dc99d5c126727f,
title = "Multiplicative method for reduction of bias in indirect digital measurement result",
abstract = "The error reduction technique, based on inverse transformation, for a shunt active resistance measurement using an ammeter and voltmeter is considered. When computing a corrected reading only multiplicative operations on two measurement results are used, namely squaring and division. The proposed method allows to increase re-sistance measurement accuracy by about two orders of magnitude what has been validated by both theoretical and experimental outcomes.",
keywords = "Bias, Error reduction technique, Indirect measurement, Shunt ohmic resistance",
author = "Muravyov, {Sergey V.} and Zlygosteva, {Galina V.} and Borikov, {Valeriy N.}",
year = "2011",
month = "9",
day = "6",
doi = "10.2478/v10178-011-0014-x",
language = "English",
volume = "18",
pages = "481--490",
journal = "Metrology and Measurement Systems",
issn = "0860-8229",
publisher = "Polish ACAD Sciences Committee Metrology and Res Equipment",
number = "3",

}

TY - JOUR

T1 - Multiplicative method for reduction of bias in indirect digital measurement result

AU - Muravyov, Sergey V.

AU - Zlygosteva, Galina V.

AU - Borikov, Valeriy N.

PY - 2011/9/6

Y1 - 2011/9/6

N2 - The error reduction technique, based on inverse transformation, for a shunt active resistance measurement using an ammeter and voltmeter is considered. When computing a corrected reading only multiplicative operations on two measurement results are used, namely squaring and division. The proposed method allows to increase re-sistance measurement accuracy by about two orders of magnitude what has been validated by both theoretical and experimental outcomes.

AB - The error reduction technique, based on inverse transformation, for a shunt active resistance measurement using an ammeter and voltmeter is considered. When computing a corrected reading only multiplicative operations on two measurement results are used, namely squaring and division. The proposed method allows to increase re-sistance measurement accuracy by about two orders of magnitude what has been validated by both theoretical and experimental outcomes.

KW - Bias

KW - Error reduction technique

KW - Indirect measurement

KW - Shunt ohmic resistance

UR - http://www.scopus.com/inward/record.url?scp=84859899900&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859899900&partnerID=8YFLogxK

U2 - 10.2478/v10178-011-0014-x

DO - 10.2478/v10178-011-0014-x

M3 - Article

AN - SCOPUS:84859899900

VL - 18

SP - 481

EP - 490

JO - Metrology and Measurement Systems

JF - Metrology and Measurement Systems

SN - 0860-8229

IS - 3

ER -