Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range

D. B. Zolotukhin, A. V. Tyunkov, Yu G. Yushkov, E. M. Oks

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

Original languageEnglish
Article number123301
JournalReview of Scientific Instruments
Volume86
Issue number12
DOIs
Publication statusPublished - 1 Dec 2015

Fingerprint

analyzers
quadrupoles
ionizers
Plasmas
residual gas
Argon
Electron beams
hydrocarbons
Hydrocarbons
argon
electron beams
Nitrogen
nitrogen
Electrodes
optimization
Oxygen
electrodes
Ions
oxygen
Gases

ASJC Scopus subject areas

  • Instrumentation

Cite this

Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range. / Zolotukhin, D. B.; Tyunkov, A. V.; Yushkov, Yu G.; Oks, E. M.

In: Review of Scientific Instruments, Vol. 86, No. 12, 123301, 01.12.2015.

Research output: Contribution to journalArticle

@article{74e769e681b34ed8adf7da5bf88e7480,
title = "Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range",
abstract = "The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.",
author = "Zolotukhin, {D. B.} and Tyunkov, {A. V.} and Yushkov, {Yu G.} and Oks, {E. M.}",
year = "2015",
month = "12",
day = "1",
doi = "10.1063/1.4937606",
language = "English",
volume = "86",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "12",

}

TY - JOUR

T1 - Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range

AU - Zolotukhin, D. B.

AU - Tyunkov, A. V.

AU - Yushkov, Yu G.

AU - Oks, E. M.

PY - 2015/12/1

Y1 - 2015/12/1

N2 - The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

AB - The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

UR - http://www.scopus.com/inward/record.url?scp=84951824981&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84951824981&partnerID=8YFLogxK

U2 - 10.1063/1.4937606

DO - 10.1063/1.4937606

M3 - Article

AN - SCOPUS:84951824981

VL - 86

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 12

M1 - 123301

ER -