Modelling of analytical peaks. Peaks modifications

S. V. Romanenko, A. G. Stromberg

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

The basic principles of symmetric peaks modifications are considered in this work. Four types of modifications-two symmetric and two asymmetric are considered in detail. Double sequent peak modification was taken as example. The dependences of peak shape parameters on modification parameters were obtained for considered examples of modifications of three basic peaks. The methods of obtaining of common sequent modifications and techniques of suitable result function choice for adequate description of analytical signal series are developed. The approximation of groups of stripping voltammetry and chromatographic peaks with some single, double and triple modifications of elementary peaks has been get. The appreciable increasing of adequacy in description of more complicated modifications was shown.

Original languageEnglish
Pages (from-to)343-354
Number of pages12
JournalAnalytica Chimica Acta
Volume581
Issue number2
DOIs
Publication statusPublished - 9 Jan 2007

Fingerprint

Voltammetry
modeling
parameter
method

Keywords

  • Analytical peak modelling
  • Chemometrics

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Modelling of analytical peaks. Peaks modifications. / Romanenko, S. V.; Stromberg, A. G.

In: Analytica Chimica Acta, Vol. 581, No. 2, 09.01.2007, p. 343-354.

Research output: Contribution to journalArticle

Romanenko, S. V. ; Stromberg, A. G. / Modelling of analytical peaks. Peaks modifications. In: Analytica Chimica Acta. 2007 ; Vol. 581, No. 2. pp. 343-354.
@article{c9484a1b091042289017e1068fa4a5f1,
title = "Modelling of analytical peaks. Peaks modifications",
abstract = "The basic principles of symmetric peaks modifications are considered in this work. Four types of modifications-two symmetric and two asymmetric are considered in detail. Double sequent peak modification was taken as example. The dependences of peak shape parameters on modification parameters were obtained for considered examples of modifications of three basic peaks. The methods of obtaining of common sequent modifications and techniques of suitable result function choice for adequate description of analytical signal series are developed. The approximation of groups of stripping voltammetry and chromatographic peaks with some single, double and triple modifications of elementary peaks has been get. The appreciable increasing of adequacy in description of more complicated modifications was shown.",
keywords = "Analytical peak modelling, Chemometrics",
author = "Romanenko, {S. V.} and Stromberg, {A. G.}",
year = "2007",
month = "1",
day = "9",
doi = "10.1016/j.aca.2006.08.028",
language = "English",
volume = "581",
pages = "343--354",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Modelling of analytical peaks. Peaks modifications

AU - Romanenko, S. V.

AU - Stromberg, A. G.

PY - 2007/1/9

Y1 - 2007/1/9

N2 - The basic principles of symmetric peaks modifications are considered in this work. Four types of modifications-two symmetric and two asymmetric are considered in detail. Double sequent peak modification was taken as example. The dependences of peak shape parameters on modification parameters were obtained for considered examples of modifications of three basic peaks. The methods of obtaining of common sequent modifications and techniques of suitable result function choice for adequate description of analytical signal series are developed. The approximation of groups of stripping voltammetry and chromatographic peaks with some single, double and triple modifications of elementary peaks has been get. The appreciable increasing of adequacy in description of more complicated modifications was shown.

AB - The basic principles of symmetric peaks modifications are considered in this work. Four types of modifications-two symmetric and two asymmetric are considered in detail. Double sequent peak modification was taken as example. The dependences of peak shape parameters on modification parameters were obtained for considered examples of modifications of three basic peaks. The methods of obtaining of common sequent modifications and techniques of suitable result function choice for adequate description of analytical signal series are developed. The approximation of groups of stripping voltammetry and chromatographic peaks with some single, double and triple modifications of elementary peaks has been get. The appreciable increasing of adequacy in description of more complicated modifications was shown.

KW - Analytical peak modelling

KW - Chemometrics

UR - http://www.scopus.com/inward/record.url?scp=33751551920&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33751551920&partnerID=8YFLogxK

U2 - 10.1016/j.aca.2006.08.028

DO - 10.1016/j.aca.2006.08.028

M3 - Article

C2 - 17386462

AN - SCOPUS:33751551920

VL - 581

SP - 343

EP - 354

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 2

ER -