Method of calculation of the distribution of an absorbed dose of a fast neutron beam of Y-120 cyclotron in biological tissue

V. A. Lisin

    Research output: Contribution to journalArticle

    Abstract

    The author proposed a method for calculation of the distribution of an absorbed dose of a fast neutron beam on Y-120 cyclotron in biological tissue. The method ensured the coincidence of the results with average experimental data with the accuracy no less than 3%, and could be used for dosimetric design of cancer therapy with fast neutrons.

    Original languageEnglish
    Pages (from-to)45-47
    Number of pages3
    JournalMedicinskaa radiologia
    Volume35
    Issue number1
    Publication statusPublished - 1990

    Fingerprint

    Neutron beams
    Cyclotrons
    Neutrons
    Tissue

    ASJC Scopus subject areas

    • Nuclear Energy and Engineering

    Cite this

    Method of calculation of the distribution of an absorbed dose of a fast neutron beam of Y-120 cyclotron in biological tissue. / Lisin, V. A.

    In: Medicinskaa radiologia, Vol. 35, No. 1, 1990, p. 45-47.

    Research output: Contribution to journalArticle

    @article{bdebda03bc4644ed9177da394882c55b,
    title = "Method of calculation of the distribution of an absorbed dose of a fast neutron beam of Y-120 cyclotron in biological tissue",
    abstract = "The author proposed a method for calculation of the distribution of an absorbed dose of a fast neutron beam on Y-120 cyclotron in biological tissue. The method ensured the coincidence of the results with average experimental data with the accuracy no less than 3{\%}, and could be used for dosimetric design of cancer therapy with fast neutrons.",
    author = "Lisin, {V. A.}",
    year = "1990",
    language = "English",
    volume = "35",
    pages = "45--47",
    journal = "Meditsinskaya Radiologiya I Radiatsionnaya Bezopasnost'",
    issn = "0025-8334",
    publisher = "Izdatel'sto Radekon",
    number = "1",

    }

    TY - JOUR

    T1 - Method of calculation of the distribution of an absorbed dose of a fast neutron beam of Y-120 cyclotron in biological tissue

    AU - Lisin, V. A.

    PY - 1990

    Y1 - 1990

    N2 - The author proposed a method for calculation of the distribution of an absorbed dose of a fast neutron beam on Y-120 cyclotron in biological tissue. The method ensured the coincidence of the results with average experimental data with the accuracy no less than 3%, and could be used for dosimetric design of cancer therapy with fast neutrons.

    AB - The author proposed a method for calculation of the distribution of an absorbed dose of a fast neutron beam on Y-120 cyclotron in biological tissue. The method ensured the coincidence of the results with average experimental data with the accuracy no less than 3%, and could be used for dosimetric design of cancer therapy with fast neutrons.

    UR - http://www.scopus.com/inward/record.url?scp=0025065792&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0025065792&partnerID=8YFLogxK

    M3 - Article

    C2 - 2308500

    AN - SCOPUS:0025065792

    VL - 35

    SP - 45

    EP - 47

    JO - Meditsinskaya Radiologiya I Radiatsionnaya Bezopasnost'

    JF - Meditsinskaya Radiologiya I Radiatsionnaya Bezopasnost'

    SN - 0025-8334

    IS - 1

    ER -