Measurement system for coating quality control during high-current process in electrolyte solution

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

This paper presents both a tool and a method for control of ceramic coating process by high pulse current in electrolytes. The method is based on the use of symmetric trapezoidal voltage pulse power source for oxidation, running volt-ampere characteristics and defining active and capacitive currents what allows to estimate the coating quality.

Original languageEnglish
Title of host publicationProceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007
Pages287-291
Number of pages5
Publication statusPublished - 2007
Event9th International Symposium on Measurement and Quality Control, ISMQC 2007 - Chennai, India
Duration: 21 Nov 200724 Nov 2007

Other

Other9th International Symposium on Measurement and Quality Control, ISMQC 2007
CountryIndia
CityChennai
Period21.11.0724.11.07

Fingerprint

Ceramic coatings
Quality control
Electrolytes
Coatings
Oxidation
Electric potential

Keywords

  • Coating quality
  • Measurement system
  • Volt-ampere characteristic

ASJC Scopus subject areas

  • Safety, Risk, Reliability and Quality

Cite this

Borikov, V. N. (2007). Measurement system for coating quality control during high-current process in electrolyte solution. In Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007 (pp. 287-291)

Measurement system for coating quality control during high-current process in electrolyte solution. / Borikov, V. N.

Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007. 2007. p. 287-291.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Borikov, VN 2007, Measurement system for coating quality control during high-current process in electrolyte solution. in Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007. pp. 287-291, 9th International Symposium on Measurement and Quality Control, ISMQC 2007, Chennai, India, 21.11.07.
Borikov VN. Measurement system for coating quality control during high-current process in electrolyte solution. In Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007. 2007. p. 287-291
Borikov, V. N. / Measurement system for coating quality control during high-current process in electrolyte solution. Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007. 2007. pp. 287-291
@inproceedings{27499bf23b5548b58c65817014626eb4,
title = "Measurement system for coating quality control during high-current process in electrolyte solution",
abstract = "This paper presents both a tool and a method for control of ceramic coating process by high pulse current in electrolytes. The method is based on the use of symmetric trapezoidal voltage pulse power source for oxidation, running volt-ampere characteristics and defining active and capacitive currents what allows to estimate the coating quality.",
keywords = "Coating quality, Measurement system, Volt-ampere characteristic",
author = "Borikov, {V. N.}",
year = "2007",
language = "English",
isbn = "8190423525",
pages = "287--291",
booktitle = "Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007",

}

TY - GEN

T1 - Measurement system for coating quality control during high-current process in electrolyte solution

AU - Borikov, V. N.

PY - 2007

Y1 - 2007

N2 - This paper presents both a tool and a method for control of ceramic coating process by high pulse current in electrolytes. The method is based on the use of symmetric trapezoidal voltage pulse power source for oxidation, running volt-ampere characteristics and defining active and capacitive currents what allows to estimate the coating quality.

AB - This paper presents both a tool and a method for control of ceramic coating process by high pulse current in electrolytes. The method is based on the use of symmetric trapezoidal voltage pulse power source for oxidation, running volt-ampere characteristics and defining active and capacitive currents what allows to estimate the coating quality.

KW - Coating quality

KW - Measurement system

KW - Volt-ampere characteristic

UR - http://www.scopus.com/inward/record.url?scp=84893421013&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893421013&partnerID=8YFLogxK

M3 - Conference contribution

SN - 8190423525

SN - 9788190423526

SP - 287

EP - 291

BT - Proceedings of the 9th International Symposium on Measurement and Quality Control, ISMQC 2007

ER -