Current shunts are widely used in metrological practice. The shunt is required to determine the value of its resistance on DC and AC currents to determine the transfer ratio error in the wide frequency band in process calibration. The paper describes a procedure for measuring the complex impedance of transfer ratio of current shunts in the frequency band using the lock-in amplifier with the differential input. The experimental results of the proposed procedure are described.

Original languageEnglish
Title of host publicationXXI IMEKO World Congress "Measurement in Research and Industry"
PublisherIMEKO-International Measurement Federation Secretariat
Publication statusPublished - 2015
Event21st IMEKO World Congress on Measurement in Research and Industry - Prague, Czech Republic
Duration: 30 Aug 20154 Sep 2015

Conference

Conference21st IMEKO World Congress on Measurement in Research and Industry
CountryCzech Republic
CityPrague
Period30.8.154.9.15

Fingerprint

Frequency bands
Calibration

Keywords

  • Calibration
  • Complex impedance
  • Current shunt
  • Lock-in amplifier
  • Transfer ratio

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Baranov, P. F., Tsimbalist, E. I., Borikov, V. N., & Soltanova, D. G. (2015). Measurement of the current transfer ratio for current shunts. In XXI IMEKO World Congress "Measurement in Research and Industry" IMEKO-International Measurement Federation Secretariat.

Measurement of the current transfer ratio for current shunts. / Baranov, Pavel F.; Tsimbalist, Edvard I.; Borikov, Valery Nikolaevich; Soltanova, Diana G.

XXI IMEKO World Congress "Measurement in Research and Industry". IMEKO-International Measurement Federation Secretariat, 2015.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Baranov, PF, Tsimbalist, EI, Borikov, VN & Soltanova, DG 2015, Measurement of the current transfer ratio for current shunts. in XXI IMEKO World Congress "Measurement in Research and Industry". IMEKO-International Measurement Federation Secretariat, 21st IMEKO World Congress on Measurement in Research and Industry, Prague, Czech Republic, 30.8.15.
Baranov PF, Tsimbalist EI, Borikov VN, Soltanova DG. Measurement of the current transfer ratio for current shunts. In XXI IMEKO World Congress "Measurement in Research and Industry". IMEKO-International Measurement Federation Secretariat. 2015
Baranov, Pavel F. ; Tsimbalist, Edvard I. ; Borikov, Valery Nikolaevich ; Soltanova, Diana G. / Measurement of the current transfer ratio for current shunts. XXI IMEKO World Congress "Measurement in Research and Industry". IMEKO-International Measurement Federation Secretariat, 2015.
@inproceedings{ffb99bca44114dd1a41df0420a919638,
title = "Measurement of the current transfer ratio for current shunts",
abstract = "Current shunts are widely used in metrological practice. The shunt is required to determine the value of its resistance on DC and AC currents to determine the transfer ratio error in the wide frequency band in process calibration. The paper describes a procedure for measuring the complex impedance of transfer ratio of current shunts in the frequency band using the lock-in amplifier with the differential input. The experimental results of the proposed procedure are described.",
keywords = "Calibration, Complex impedance, Current shunt, Lock-in amplifier, Transfer ratio",
author = "Baranov, {Pavel F.} and Tsimbalist, {Edvard I.} and Borikov, {Valery Nikolaevich} and Soltanova, {Diana G.}",
year = "2015",
language = "English",
booktitle = "XXI IMEKO World Congress {"}Measurement in Research and Industry{"}",
publisher = "IMEKO-International Measurement Federation Secretariat",

}

TY - GEN

T1 - Measurement of the current transfer ratio for current shunts

AU - Baranov, Pavel F.

AU - Tsimbalist, Edvard I.

AU - Borikov, Valery Nikolaevich

AU - Soltanova, Diana G.

PY - 2015

Y1 - 2015

N2 - Current shunts are widely used in metrological practice. The shunt is required to determine the value of its resistance on DC and AC currents to determine the transfer ratio error in the wide frequency band in process calibration. The paper describes a procedure for measuring the complex impedance of transfer ratio of current shunts in the frequency band using the lock-in amplifier with the differential input. The experimental results of the proposed procedure are described.

AB - Current shunts are widely used in metrological practice. The shunt is required to determine the value of its resistance on DC and AC currents to determine the transfer ratio error in the wide frequency band in process calibration. The paper describes a procedure for measuring the complex impedance of transfer ratio of current shunts in the frequency band using the lock-in amplifier with the differential input. The experimental results of the proposed procedure are described.

KW - Calibration

KW - Complex impedance

KW - Current shunt

KW - Lock-in amplifier

KW - Transfer ratio

UR - http://www.scopus.com/inward/record.url?scp=84951032642&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84951032642&partnerID=8YFLogxK

M3 - Conference contribution

BT - XXI IMEKO World Congress "Measurement in Research and Industry"

PB - IMEKO-International Measurement Federation Secretariat

ER -