Low voltage triggering of a pseudospark switch

Yu D. Korolev, I. A. Shemyakin, O. B. Frants, K. Frank

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    1 Citation (Scopus)

    Abstract

    Experimental data on triggering of a pseudospark switch with a trigger unit based on auxiliary glow discharge are presented. Due to modifications in the trigger electric circuit, the switch is triggered starting from a voltage of 50 V at a current level of several mAmps. With a voltage of 150 - 200 V the delay time to triggering does not exceed 200 ns.

    Original languageEnglish
    Title of host publicationInternational Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV
    Place of PublicationPiscataway, NJ, United States
    PublisherIEEE
    Pages335-338
    Number of pages4
    Volume1
    Publication statusPublished - 2000

    Fingerprint

    Switches
    Glow discharges
    Electric potential
    Time delay
    Networks (circuits)

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Korolev, Y. D., Shemyakin, I. A., Frants, O. B., & Frank, K. (2000). Low voltage triggering of a pseudospark switch. In International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV (Vol. 1, pp. 335-338). Piscataway, NJ, United States: IEEE.

    Low voltage triggering of a pseudospark switch. / Korolev, Yu D.; Shemyakin, I. A.; Frants, O. B.; Frank, K.

    International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. Vol. 1 Piscataway, NJ, United States : IEEE, 2000. p. 335-338.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Korolev, YD, Shemyakin, IA, Frants, OB & Frank, K 2000, Low voltage triggering of a pseudospark switch. in International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. vol. 1, IEEE, Piscataway, NJ, United States, pp. 335-338.
    Korolev YD, Shemyakin IA, Frants OB, Frank K. Low voltage triggering of a pseudospark switch. In International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. Vol. 1. Piscataway, NJ, United States: IEEE. 2000. p. 335-338
    Korolev, Yu D. ; Shemyakin, I. A. ; Frants, O. B. ; Frank, K. / Low voltage triggering of a pseudospark switch. International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. Vol. 1 Piscataway, NJ, United States : IEEE, 2000. pp. 335-338
    @inproceedings{f4a474eb67e94d5b89b3fb4ede30ed33,
    title = "Low voltage triggering of a pseudospark switch",
    abstract = "Experimental data on triggering of a pseudospark switch with a trigger unit based on auxiliary glow discharge are presented. Due to modifications in the trigger electric circuit, the switch is triggered starting from a voltage of 50 V at a current level of several mAmps. With a voltage of 150 - 200 V the delay time to triggering does not exceed 200 ns.",
    author = "Korolev, {Yu D.} and Shemyakin, {I. A.} and Frants, {O. B.} and K. Frank",
    year = "2000",
    language = "English",
    volume = "1",
    pages = "335--338",
    booktitle = "International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV",
    publisher = "IEEE",

    }

    TY - GEN

    T1 - Low voltage triggering of a pseudospark switch

    AU - Korolev, Yu D.

    AU - Shemyakin, I. A.

    AU - Frants, O. B.

    AU - Frank, K.

    PY - 2000

    Y1 - 2000

    N2 - Experimental data on triggering of a pseudospark switch with a trigger unit based on auxiliary glow discharge are presented. Due to modifications in the trigger electric circuit, the switch is triggered starting from a voltage of 50 V at a current level of several mAmps. With a voltage of 150 - 200 V the delay time to triggering does not exceed 200 ns.

    AB - Experimental data on triggering of a pseudospark switch with a trigger unit based on auxiliary glow discharge are presented. Due to modifications in the trigger electric circuit, the switch is triggered starting from a voltage of 50 V at a current level of several mAmps. With a voltage of 150 - 200 V the delay time to triggering does not exceed 200 ns.

    UR - http://www.scopus.com/inward/record.url?scp=0034474301&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0034474301&partnerID=8YFLogxK

    M3 - Conference contribution

    VL - 1

    SP - 335

    EP - 338

    BT - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV

    PB - IEEE

    CY - Piscataway, NJ, United States

    ER -