Instrument for In-Process Control of Capacitance per Unit Length of an Electrical Wire

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

A theoretical description and practical realization of a method for in-process control of the capacitance per unit length of a single core electrical wire are given. The standards regulating measurement of wire capacitance are presented and the limitedness of their use for in-process control is pointed out. Methods of primary and operating adjustments of the capacitance meter minimizing the measurement error are developed. The problem of determining the actual values of the capacitance of wire specimens is examined. The design, operating principle, and results of factory tests of the CAP-10 capacitance meter are described.

Original languageEnglish
Pages (from-to)278-283
Number of pages6
JournalMeasurement Techniques
Volume61
Issue number3
DOIs
Publication statusPublished - 1 Jun 2018

Fingerprint

Unit of length
Capacitance
Process Control
Process control
capacitance
wire
Wire
Cable cores
Measurement errors
industrial plants
Measurement Error
Industrial plants
Adjustment
adjusting

Keywords

  • adjustment
  • capacitance per unit length
  • permittivity
  • real capacitance value
  • single core wire
  • Translated from Izmeritel’naya Tekhnika, No. 3, pp. 46–50, March, 2018
  • water conductivity

ASJC Scopus subject areas

  • Instrumentation
  • Applied Mathematics

Cite this

Instrument for In-Process Control of Capacitance per Unit Length of an Electrical Wire. / Vavilova, G. V.; Gol’dshtein, A. E.

In: Measurement Techniques, Vol. 61, No. 3, 01.06.2018, p. 278-283.

Research output: Contribution to journalArticle

@article{4da5075e1b744756b1479f1822f49832,
title = "Instrument for In-Process Control of Capacitance per Unit Length of an Electrical Wire",
abstract = "A theoretical description and practical realization of a method for in-process control of the capacitance per unit length of a single core electrical wire are given. The standards regulating measurement of wire capacitance are presented and the limitedness of their use for in-process control is pointed out. Methods of primary and operating adjustments of the capacitance meter minimizing the measurement error are developed. The problem of determining the actual values of the capacitance of wire specimens is examined. The design, operating principle, and results of factory tests of the CAP-10 capacitance meter are described.",
keywords = "adjustment, capacitance per unit length, permittivity, real capacitance value, single core wire, Translated from Izmeritel’naya Tekhnika, No. 3, pp. 46–50, March, 2018, water conductivity",
author = "Vavilova, {G. V.} and Gol’dshtein, {A. E.}",
year = "2018",
month = "6",
day = "1",
doi = "10.1007/s11018-018-1421-6",
language = "English",
volume = "61",
pages = "278--283",
journal = "Measurement Techniques",
issn = "0543-1972",
publisher = "Springer Science and Business Media Deutschland GmbH",
number = "3",

}

TY - JOUR

T1 - Instrument for In-Process Control of Capacitance per Unit Length of an Electrical Wire

AU - Vavilova, G. V.

AU - Gol’dshtein, A. E.

PY - 2018/6/1

Y1 - 2018/6/1

N2 - A theoretical description and practical realization of a method for in-process control of the capacitance per unit length of a single core electrical wire are given. The standards regulating measurement of wire capacitance are presented and the limitedness of their use for in-process control is pointed out. Methods of primary and operating adjustments of the capacitance meter minimizing the measurement error are developed. The problem of determining the actual values of the capacitance of wire specimens is examined. The design, operating principle, and results of factory tests of the CAP-10 capacitance meter are described.

AB - A theoretical description and practical realization of a method for in-process control of the capacitance per unit length of a single core electrical wire are given. The standards regulating measurement of wire capacitance are presented and the limitedness of their use for in-process control is pointed out. Methods of primary and operating adjustments of the capacitance meter minimizing the measurement error are developed. The problem of determining the actual values of the capacitance of wire specimens is examined. The design, operating principle, and results of factory tests of the CAP-10 capacitance meter are described.

KW - adjustment

KW - capacitance per unit length

KW - permittivity

KW - real capacitance value

KW - single core wire

KW - Translated from Izmeritel’naya Tekhnika, No. 3, pp. 46–50, March, 2018

KW - water conductivity

UR - http://www.scopus.com/inward/record.url?scp=85049581525&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049581525&partnerID=8YFLogxK

U2 - 10.1007/s11018-018-1421-6

DO - 10.1007/s11018-018-1421-6

M3 - Article

AN - SCOPUS:85049581525

VL - 61

SP - 278

EP - 283

JO - Measurement Techniques

JF - Measurement Techniques

SN - 0543-1972

IS - 3

ER -