Influence of an external magnetic field on the electroerosive surface wear of the accelerating channel in a coaxial magnetic-plasma accelerator

A. S. Saigash, A. A. Sivkov, D. Yu Gerasimov, R. R. Sharipov, S. I. Privezentsev

Research output: Contribution to journalArticle

Abstract

It is shown that electroerosive surface wear of the accelerating channel increases significantly if the screening is reduced. The wear over the channel length may be equalized by greater screening in the initial section.

Original languageEnglish
Pages (from-to)30-34
Number of pages5
JournalRussian Electrical Engineering
Volume77
Issue number12
Publication statusPublished - 2006

Fingerprint

Plasma accelerators
Screening
Wear of materials
Magnetic fields

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

@article{e8833cec8d7d4cbe9c9af9ee62411bf0,
title = "Influence of an external magnetic field on the electroerosive surface wear of the accelerating channel in a coaxial magnetic-plasma accelerator",
abstract = "It is shown that electroerosive surface wear of the accelerating channel increases significantly if the screening is reduced. The wear over the channel length may be equalized by greater screening in the initial section.",
author = "Saigash, {A. S.} and Sivkov, {A. A.} and Gerasimov, {D. Yu} and Sharipov, {R. R.} and Privezentsev, {S. I.}",
year = "2006",
language = "English",
volume = "77",
pages = "30--34",
journal = "Russian Electrical Engineering",
issn = "1068-3712",
publisher = "Allerton Press Inc.",
number = "12",

}

TY - JOUR

T1 - Influence of an external magnetic field on the electroerosive surface wear of the accelerating channel in a coaxial magnetic-plasma accelerator

AU - Saigash, A. S.

AU - Sivkov, A. A.

AU - Gerasimov, D. Yu

AU - Sharipov, R. R.

AU - Privezentsev, S. I.

PY - 2006

Y1 - 2006

N2 - It is shown that electroerosive surface wear of the accelerating channel increases significantly if the screening is reduced. The wear over the channel length may be equalized by greater screening in the initial section.

AB - It is shown that electroerosive surface wear of the accelerating channel increases significantly if the screening is reduced. The wear over the channel length may be equalized by greater screening in the initial section.