Abstract

Hydrogen permeability through diaphragms made of 12X18H12T stainless steel and Pd60Ag40 alloy under electrolytic hydrogen saturation has been studied with an electrolytic cell with a vacuum chamber. Hydrogen diffusion constants DH = 3.86 × 10-10 cm2 s-1 for stainless steel and DH = 4.36 × 10-8 cm2 s-1 for Pd60Ag40 alloy have been determined at a temperature of 40°C using the Berrer relations.

Original languageEnglish
Pages (from-to)534-537
Number of pages4
JournalJournal of Surface Investigation
Volume4
Issue number3
DOIs
Publication statusPublished - 1 Jun 2010

ASJC Scopus subject areas

  • Surfaces, Coatings and Films

Fingerprint Dive into the research topics of 'Hydrogen diffusion constants in stainless steel and Pd60Ag40 alloy, and permeability of diaphragms made of these metals'. Together they form a unique fingerprint.