HPLC Monitoring of Biphenyl Derivatives with UV and Electrochemical Detection Modes

Jiri Zima, Silvie Vaingatova, Jiri Barek, Jiri Brichac

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

A new RP HPLC method for the separation of amino, nitro and hydroxy derivatives of 2- and 4-substituted biphenyls as model genotoxic compounds and their metabolic products has been developed. A newly designed amperometric platinum tubular detector was employed to obtain lower detection limit than with the classical UV detector. The method has been applied to the monitoring the destruction efficiency of the studied genotoxic compounds in laboratory waste, as well as to the determination of 2-hydroxybiphenyl content in tomatoes and in human urine.

Original languageEnglish
Pages (from-to)805-816
Number of pages12
JournalChemia Analityczna
Volume48
Issue number5
Publication statusPublished - 16 Dec 2003
Externally publishedYes

Fingerprint

Ultraviolet detectors
Platinum
Derivatives
Detectors
Monitoring
diphenyl
2-phenylphenol

Keywords

  • Aminobiphenyls
  • Electrochemical detection
  • HPLC separation
  • Hydroxybiphenyls
  • Nitrobiphenyls

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

HPLC Monitoring of Biphenyl Derivatives with UV and Electrochemical Detection Modes. / Zima, Jiri; Vaingatova, Silvie; Barek, Jiri; Brichac, Jiri.

In: Chemia Analityczna, Vol. 48, No. 5, 16.12.2003, p. 805-816.

Research output: Contribution to journalArticle

Zima, J, Vaingatova, S, Barek, J & Brichac, J 2003, 'HPLC Monitoring of Biphenyl Derivatives with UV and Electrochemical Detection Modes', Chemia Analityczna, vol. 48, no. 5, pp. 805-816.
Zima, Jiri ; Vaingatova, Silvie ; Barek, Jiri ; Brichac, Jiri. / HPLC Monitoring of Biphenyl Derivatives with UV and Electrochemical Detection Modes. In: Chemia Analityczna. 2003 ; Vol. 48, No. 5. pp. 805-816.
@article{12848e81da7341baa21cb20d0e6be5c0,
title = "HPLC Monitoring of Biphenyl Derivatives with UV and Electrochemical Detection Modes",
abstract = "A new RP HPLC method for the separation of amino, nitro and hydroxy derivatives of 2- and 4-substituted biphenyls as model genotoxic compounds and their metabolic products has been developed. A newly designed amperometric platinum tubular detector was employed to obtain lower detection limit than with the classical UV detector. The method has been applied to the monitoring the destruction efficiency of the studied genotoxic compounds in laboratory waste, as well as to the determination of 2-hydroxybiphenyl content in tomatoes and in human urine.",
keywords = "Aminobiphenyls, Electrochemical detection, HPLC separation, Hydroxybiphenyls, Nitrobiphenyls",
author = "Jiri Zima and Silvie Vaingatova and Jiri Barek and Jiri Brichac",
year = "2003",
month = "12",
day = "16",
language = "English",
volume = "48",
pages = "805--816",
journal = "Chemia Analityczna",
issn = "0009-2223",
publisher = "Polskie Towarzystwo Chemiczne",
number = "5",

}

TY - JOUR

T1 - HPLC Monitoring of Biphenyl Derivatives with UV and Electrochemical Detection Modes

AU - Zima, Jiri

AU - Vaingatova, Silvie

AU - Barek, Jiri

AU - Brichac, Jiri

PY - 2003/12/16

Y1 - 2003/12/16

N2 - A new RP HPLC method for the separation of amino, nitro and hydroxy derivatives of 2- and 4-substituted biphenyls as model genotoxic compounds and their metabolic products has been developed. A newly designed amperometric platinum tubular detector was employed to obtain lower detection limit than with the classical UV detector. The method has been applied to the monitoring the destruction efficiency of the studied genotoxic compounds in laboratory waste, as well as to the determination of 2-hydroxybiphenyl content in tomatoes and in human urine.

AB - A new RP HPLC method for the separation of amino, nitro and hydroxy derivatives of 2- and 4-substituted biphenyls as model genotoxic compounds and their metabolic products has been developed. A newly designed amperometric platinum tubular detector was employed to obtain lower detection limit than with the classical UV detector. The method has been applied to the monitoring the destruction efficiency of the studied genotoxic compounds in laboratory waste, as well as to the determination of 2-hydroxybiphenyl content in tomatoes and in human urine.

KW - Aminobiphenyls

KW - Electrochemical detection

KW - HPLC separation

KW - Hydroxybiphenyls

KW - Nitrobiphenyls

UR - http://www.scopus.com/inward/record.url?scp=0344628511&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0344628511&partnerID=8YFLogxK

M3 - Article

VL - 48

SP - 805

EP - 816

JO - Chemia Analityczna

JF - Chemia Analityczna

SN - 0009-2223

IS - 5

ER -