Abstract
Presented in this paper are the results of the experiments with Ar gas-puff on the inductive storage generator GIT-4 (1.2 MJ). A single shell gas-puff and double shell gas-puff were used. Implosion of gas-puff was monitored by the following diagnostics: filtered x-ray diodes, optic streak camera, and time integrated x-ray pinhole camera. It was shown that in the case of double gas-puff power and energy of Ar K-shell emission increase from 1.10 10W to 2.2 10 10W and from 190 J to 350 J accordingly, power of soft x-ray emission increase insufficiently.
Original language | English |
---|---|
Title of host publication | IEEE International Conference on Plasma Science |
Publisher | IEEE |
Pages | 149 |
Number of pages | 1 |
Publication status | Published - 1994 |
Externally published | Yes |
Event | Proceedings of the IEEE International Conference on Plasma Science - Santa Fe, NM, USA Duration: 6 Jun 1994 → 8 Jun 1994 |
Other
Other | Proceedings of the IEEE International Conference on Plasma Science |
---|---|
City | Santa Fe, NM, USA |
Period | 6.6.94 → 8.6.94 |
ASJC Scopus subject areas
- Condensed Matter Physics