The construction of a generator with an inductive storage device is described, together with that of its exploding-wire contact breaker, which allows a current of up to 25 ka to be developed in the active load, with a growth time of 40 nsec and a voltage amplitude of 500 kv. Similarity criteria are presented for simulating various parameters of the high-voltage pulses in such generators.
Original language | English |
---|---|
Title of host publication | Instrum Exp Tech |
Pages | 1673-1675 |
Number of pages | 3 |
Volume | 17 |
Edition | 6 pt 2 |
Publication status | Published - Nov 1974 |
ASJC Scopus subject areas
- Engineering(all)