Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation

K. Kruchinin, S. T. Boogert, P. Karataev, L. J. Nevay, B. Bolzon, T. Lefevre, S. Mazzoni, A. Aryshev, M. Shevelev, N. Terunuma, J. Urakawa

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Transition radiation (TR) appearing when relativistic uniformly moving charged particle (or bunch of particles) crosses a boundary between two media with different dielectric properties is widely used as a tool for diagnostics of particle beams in modern accelerator facilities. The best resolution which can be achieved using beam profile monitors based on TR in optical wave range has a limitation caused by a spatial resolution of an optical system. Using a method based on analyzing a visibility of the TR Point Spread Function one can achieve a sub-micrometer resolution. In this report we shall represent the recent experimental results of a micron-scale beam size measurement at KEK-ATF2. We shall discuss the hardware status and future plans.

Original languageEnglish
Title of host publicationIBIC 2013
Subtitle of host publicationProceedings of the 2nd International Beam Instrumentation Conference
PublisherJoint Accelerator Conferences Website (JACoW)
Pages615-618
Number of pages4
ISBN (Electronic)9783954501274
Publication statusPublished - 1 Dec 2013
Externally publishedYes
Event2nd International Beam Instrumentation Conference, IBIC 2013 - Oxford, United Kingdom
Duration: 16 Sep 201319 Sep 2013

Conference

Conference2nd International Beam Instrumentation Conference, IBIC 2013
CountryUnited Kingdom
CityOxford
Period16.9.1319.9.13

Fingerprint

Optical transitions
emittance
optical transition
micrometers
Radiation
radiation
Particle beams
Optical transfer function
particle beams
Charged particles
point spread functions
visibility
Visibility
Optical systems
Dielectric properties
Particle accelerators
monitors
dielectric properties
charged particles
hardware

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Kruchinin, K., Boogert, S. T., Karataev, P., Nevay, L. J., Bolzon, B., Lefevre, T., ... Urakawa, J. (2013). Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation. In IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference (pp. 615-618). Joint Accelerator Conferences Website (JACoW).

Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation. / Kruchinin, K.; Boogert, S. T.; Karataev, P.; Nevay, L. J.; Bolzon, B.; Lefevre, T.; Mazzoni, S.; Aryshev, A.; Shevelev, M.; Terunuma, N.; Urakawa, J.

IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW), 2013. p. 615-618.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kruchinin, K, Boogert, ST, Karataev, P, Nevay, LJ, Bolzon, B, Lefevre, T, Mazzoni, S, Aryshev, A, Shevelev, M, Terunuma, N & Urakawa, J 2013, Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation. in IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW), pp. 615-618, 2nd International Beam Instrumentation Conference, IBIC 2013, Oxford, United Kingdom, 16.9.13.
Kruchinin K, Boogert ST, Karataev P, Nevay LJ, Bolzon B, Lefevre T et al. Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation. In IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW). 2013. p. 615-618
Kruchinin, K. ; Boogert, S. T. ; Karataev, P. ; Nevay, L. J. ; Bolzon, B. ; Lefevre, T. ; Mazzoni, S. ; Aryshev, A. ; Shevelev, M. ; Terunuma, N. ; Urakawa, J. / Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation. IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW), 2013. pp. 615-618
@inproceedings{8a635003646f453484c29999c5d309cd,
title = "Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation",
abstract = "Transition radiation (TR) appearing when relativistic uniformly moving charged particle (or bunch of particles) crosses a boundary between two media with different dielectric properties is widely used as a tool for diagnostics of particle beams in modern accelerator facilities. The best resolution which can be achieved using beam profile monitors based on TR in optical wave range has a limitation caused by a spatial resolution of an optical system. Using a method based on analyzing a visibility of the TR Point Spread Function one can achieve a sub-micrometer resolution. In this report we shall represent the recent experimental results of a micron-scale beam size measurement at KEK-ATF2. We shall discuss the hardware status and future plans.",
author = "K. Kruchinin and Boogert, {S. T.} and P. Karataev and Nevay, {L. J.} and B. Bolzon and T. Lefevre and S. Mazzoni and A. Aryshev and M. Shevelev and N. Terunuma and J. Urakawa",
year = "2013",
month = "12",
day = "1",
language = "English",
pages = "615--618",
booktitle = "IBIC 2013",
publisher = "Joint Accelerator Conferences Website (JACoW)",

}

TY - GEN

T1 - Extremely low emittance beam size diagnostics with sub-micrometer resolution using optical transition radiation

AU - Kruchinin, K.

AU - Boogert, S. T.

AU - Karataev, P.

AU - Nevay, L. J.

AU - Bolzon, B.

AU - Lefevre, T.

AU - Mazzoni, S.

AU - Aryshev, A.

AU - Shevelev, M.

AU - Terunuma, N.

AU - Urakawa, J.

PY - 2013/12/1

Y1 - 2013/12/1

N2 - Transition radiation (TR) appearing when relativistic uniformly moving charged particle (or bunch of particles) crosses a boundary between two media with different dielectric properties is widely used as a tool for diagnostics of particle beams in modern accelerator facilities. The best resolution which can be achieved using beam profile monitors based on TR in optical wave range has a limitation caused by a spatial resolution of an optical system. Using a method based on analyzing a visibility of the TR Point Spread Function one can achieve a sub-micrometer resolution. In this report we shall represent the recent experimental results of a micron-scale beam size measurement at KEK-ATF2. We shall discuss the hardware status and future plans.

AB - Transition radiation (TR) appearing when relativistic uniformly moving charged particle (or bunch of particles) crosses a boundary between two media with different dielectric properties is widely used as a tool for diagnostics of particle beams in modern accelerator facilities. The best resolution which can be achieved using beam profile monitors based on TR in optical wave range has a limitation caused by a spatial resolution of an optical system. Using a method based on analyzing a visibility of the TR Point Spread Function one can achieve a sub-micrometer resolution. In this report we shall represent the recent experimental results of a micron-scale beam size measurement at KEK-ATF2. We shall discuss the hardware status and future plans.

UR - http://www.scopus.com/inward/record.url?scp=84920540834&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920540834&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84920540834

SP - 615

EP - 618

BT - IBIC 2013

PB - Joint Accelerator Conferences Website (JACoW)

ER -